System Menu
- 44 -
10.3.3.3
Linking of Outputs with Functions
Chapter
15 I/O Configuration Notation Table contains an overview of all functions which can be assigned to
the inputs. After selecting a function via parameter system
I/O-configuration
output function by using the
navigation buttons. The desired output for this function can be selected by pressing the ENTER button.
If a previously used output needs to be reset, the button can be used, to set the output to the “not used”
state. Further it is possible to press the ENTER key repeatedly until “not-used” appears in the display. A multiple
use of outputs is not possible here. If an input is already used, only the next free output can be chosen automati-
cally.
Figure 14: Output assignment
10.3.3.4
Output-Logic Assignment
The outputs can also be assigned with an active HIGH or LOW logic depending on the selected output function.
The setting follows the same procedure as already described in section
10.4
System: Default Parameters
With this parameter, the device can be reset to its factory settings (default parameters).
Possible key functions are:
Cancel the operation
The factory parameters are loaded immediately and then effective. All values
and configurations previously stored in the controller are deleted / overwritten!
WARNING!
By loading the factory parameters, all individually configured or customer-specific parameter
settings as well as assignments of the inputs and outputs are lost.
It is recommended to note the original settings on a sheet of paper before the control is reset.
You can also use our note table for your individual I / O configuration (see chapter
OUT assignment 1/23
drive signal 1 X-axis
ST5 (S11) - P03
drive signal 2 X-axis
ST5 (S11) - P04
drive signal 3 X-axis
ST5 (S11) - P05
OUT logic 1/23
drive signal 1 X-axis
high active
drive signal 2 X-axis
high active
drive signal 3 X-axis
high active
F3
F2