System Menu
- 42 -
10.3.2
Output Functions
Position reached (wiping / statically)
If 0.0 s is entered in parameter axis
X-/Y-axis
times
pos. reached, the output switches statically
i.e. the output is active, after the target value has been reached.
If a wiping time between 0.1 … 99.9 s is entered, the output will be active until the entered wiping time
has expired.
Drive Signal
The drive signal outputs are individually configurable via parameter axis
X-/Y-axis
settings
drivesignals (
9.3).
Control enable
Before a positioning the signal control enable is set. After reaching the target position and only after
expiration of the time in parameter axis
X-/Y-axis
times
delay contr.enable, the signal control
enable is reset.
Quantity reached (wiping / statically)
If 0.0 s is entered in parameter axis
X-/Y-axis
times
quantity reached, the output is set statically
when the quantity is reached. When pressing START, the output is reset.
If a wiping time between 0.1 … 99.9 s is entered, the output will be active until the entered wiping time
has expired.
Tolerance window <
Axis
>
If the current actual position corresponds to the target value +/- the value entered in parameter axis
X-/Y-axis
distances
tolerancewindow, this output is set.
Reference drive
This output is set during a reference drive
Tool enable
In manual mode:
the output is set when changing into the manual mode and is reset
during a positioning.
In single and program mode:
the output is reset when changing in one of these modes and is
set after each positioning. The output can be reset via STOP button.
Program - end
The output is set, after the program block with end marker has been proceseed. If „program“ resp.
„auto-program“ has been selected in system
setup
auxiliary counter, the number of program se-
quences has to be reached additionally.