Technical Data
- 14 -
8.5
Dimensions Magnetic Tape
Figure 5: Dimensions Magnetic Tape
8.6
Technical Data Sensor
LIMAX2 (Standard version)
Mechanical Data
Measuring principle
absolute
Repeat accuracy
±1 Increment
System accuracy in µm at 20°C
±(1000 + 50 x L) L = measuring length in meter
Distance sensor - magnetic tape
max. 4 mm
Basic pole pitch
8 mm
Sensor housing material
aluminium
Sensor housing dimensions
L x W x H = 246 x 55 x 55 mm
Necessary type
AB20-80-10-1-R-D-15-BK80
Maximum measuring length
260 m
Connection
Open cable ends (more options
Sensor cable
3 m standard cable length (other on request)
Weight
approx. 460 g without cable (cable approx. 60 g/m)
Electrical Data
Supply voltage
10 … 30 VDC
Residual ripple
10 … 30 VDC < 10%
Power input
max. 200 mA
Interfaces
SSI, CAN, CANopen (DS406, DS417), RS422, RS232, RS485, PROFIBUS
Resolution
According to the Type Designation (
Speed
max. 10 m/s (higher speeds on request)
Conditions
Storage temperature
-20 … +85° C
Operation temperature
-10 … +70° C
(-25 … +85° C on request)
Humidity
max. 95 %, not condensing
Protection class
IP50 (IP54 on request)
Scale 5:1