background image

 

 

 
 

 

Operating Manual 

SERIES 

GMIX2 

Magnetic Incremental Linear Encoder for large Measuring Distances 

 

 

 

Predestined for applications in storage and conveyor technology 

 

Mounting distance from sensor to magnetic tape up to 4 mm  

 

Compact sensor head with integrated evaluation electronics 

 

Magnetic measuring principle with contactless scanning 

 

Speed proportional square wave signal outputs 

 

Wear-free scanning of the magnetic tape  

 

Resolution 2.5 mm (at 4-edge triggering) 

 

Insensitive to dust, dirt and water  

 

High IP67 protection class 

 

Quick and easy to install 

799000019 / Rev. 0 / 2019-09-24 

Translation of the original operating manual 

Содержание GMIX2 Series

Страница 1: ...p to 4 mm Compact sensor head with integrated evaluation electronics Magnetic measuring principle with contactless scanning Speed proportional square wave signal outputs Wear free scanning of the magn...

Страница 2: ...Str 1 D 78239 Rielasingen Worblingen Technical Support 49 0 7731 9339 0 49 0 7731 2 88 03 info elgo de Document No 799000019 Document Name GMIX2 000 MA E_39 19 Document Revision Rev 0 Issue Date 2019...

Страница 3: ...7 5 Product Features 8 5 1 Functional Principle 8 5 2 Pulse Diagram 8 6 Technical Data 9 6 1 Identification 9 6 2 Sensor Dimensions 9 6 3 Technical Data Sensor 10 6 4 Technical Data Magnetic Tape 11...

Страница 4: ...of the magnetic tape 13 Figure 6 Handling 14 Figure 7 Mounting tolerances 16 Figure 8 Alignment of the sensor to the magnetic tape 17 Figure 9 Alignment of the sensor to the magnetic ring 18 3 List o...

Страница 5: ...symbol in connection with the signal word Danger indicates an immediate danger for the life and health of persons Failure to heed these instructions can result in serious damage to health and even fat...

Страница 6: ...mpany is obliged to take appropriate safety measure The initial operation may only be performed by qualified and trained staff Selection and installation of the devices as well as their embedding into...

Страница 7: ...r Transport Unpacking and Loading CAUTION Transport the package box palette etc professionally Do not throw hit or fold it 4 9 Handling of Packaging Material Notes for proper disposal 4 4 4 10 Inspect...

Страница 8: ...d for applications in storage or conveyor technology or for longer measuring distances Thanks to the wear free magnetic measuring principle and the high IP67 protection class the sensor always works u...

Страница 9: ...of the device and indicates the exact type designation order reference 9 with the corresponding part number Furthermore the type label contains a unique traceable device number When corresponding with...

Страница 10: ...heoretically unlimited Connections open cable ends Sensor cable 1 5 m standard cable length others on request drag chain suitable Sensor cable bending radius min 60 mm Weight sensor head approx 25 g w...

Страница 11: ...9088 observe instructions others on request Width 10 mm Height magnetic tape without back iron stripe 1 05 mm 0 10 with back iron without adhesive tape 1 35 mm 0 11 with back iron adhesive tape witho...

Страница 12: ...not be installed close to sources of strong inductive or capacitive interference or strong electrostatic fields CAUTION The electrical connections must be made by suitably qualified personnel in accor...

Страница 13: ...ic tape consists of 2 pre assembled components see Figure 7 Components of the magnetic tape below A magnetized flexible plastic tape Pos 3 which is connected with a magnetically conductive steel tape...

Страница 14: ...4 5 kg cm2 Gluing temperature The optimal gluing temperature is between 18 C and 30 C Avoid colder sticking sur faces than 10 C because in this case the adhesive becomes too hard and perhaps a suffici...

Страница 15: ...over tape under great pressure 8 Safeguard the ends of the cover tape against peeling off e g by using end caps 9 1 7 2 1 Resistance against Chemical Influence Table 1 Resistance against Chemical Infl...

Страница 16: ...g installation the specified installation tolerances must also be adhered to 7 3 1 Mounting Tolerances Table 2 Mounting tolerances Magnetic tape MB20 50 10 1 R Sensor distance to the tape max 4 0 mm L...

Страница 17: ...tic tape the center of the sensor is aligned to the center of the magnetic tape Both active sensor areas see red hatched surfaces in the figure below must be guided over the tape at the permitted dist...

Страница 18: ...e see top view Figure 9 Alignment of the sensor to the magnetic ring Available magnet rings can be found in section 9 1 Accessories NOTE Please make sure that the mounting tolerances see section 7 3 1...

Страница 19: ...eed as follows 1 Installation of RC circuits via contactor coils of AC contactors e g 0 1 F 100 2 Installation of recovery diodes via DC inductors 3 Installation of RC circuits via the different motor...

Страница 20: ...of the magnetic tape FS1000 FS1500 or FS2000 Guide rail for magnetic tape length 1 0 m 1 5 m and max 2 0 m available For longer measuring lengths the rails can be lined up together AP 00 XX Aluminium...

Страница 21: ...21 Notes...

Страница 22: ...22 Notes...

Страница 23: ...9 Installation 13 Magnetic tape structure 12 Maintenance 21 Mounting the Evaluation Box 14 Mounting the Sensor Head 14 Mounting Tolerances 14 Operating area 13 Operational safety 5 Order reference 9...

Страница 24: ...GMIX2 000 MA E_39 19 Subject to change 2019 ELGO Electronic GmbH Co KG ELGO Electronic GmbH Co KG Measuring Positioning Control Carl Benz Str 1 D 78239 Rielasingen Fon 49 0 7731 9339 0 Fax 49 0 7731...

Отзывы: