Installation and First Start-Up
- 15 -
5.3
Installation of the Sensor
For mounting the sensor two M3 screws are required. Observe the tolerances stated below.
5.3.1
Mechanical Tolerances
Tolerances
Magnetic tape type
MB20-20-10-1-R
Ride height
0.1 mm…max. 0.8 mm
Pitch
The maximum distance of 0.8 mm must not be exceeded at any position
Yaw angle
+/- 5 °
Roll
The maximum distance of 0.8 mm must not be exceeded at any position
Lateral offset
+/- 2.5 mm
Figure 6: Tolerances