3. Determination of the rail and tape length 

Basically the following applies with an order of magnetic tape: 

 

  

Ordered length of tape = effective measuring di 100 mm

  

 

For further details see the  „Type designation“ at the end of the manual. 

 

4. Display assignment 

 
 
 
 
 
 

5. The AZ16E in operation   

5.1 Initial operation 

5.1.1 Detection of measuring direction 

The Magnet Sensor „AZS“ and the magnetic tape are provided with a marker, in order to signal 

the installation direction. The markings of sensor and tape must point to the same direction. 

 

The counting direction (+/-) is reversible in parameter 

P01

 (see chapter 5.4). 

 
 
 
 
 
 
 
 

 

5.1.2  Referencing 

Setting the zero-point:

 A new AZ16E unit shows always the absolute value of the magnetic 

tape and should be calibrated to the zero point for one time. The reference value default setting in 

register 

P09 

is 

0

. To assign a zero point to an arbitrary position, move to the desired  

zero-point and press the buttons 

F + Set 

together. 

 

Reference value:

 Alternatively an arbitrary value can be entered in 

P09

, to set a demanded ref-

erence measurement by pressing 

F + Set

 together. 

 

 

 

 

                  battery condition     direction arrow     tool offset 3 (1, 2 or 3 possible) 

                                                                                                            absolute mode 
 
          sign                                                                                             measurement unit 

Sensor bottom  

Positive Counting Direction  

(if P01 = Default setting) 

Tape (top view, scanning side) 

Содержание AZ16E Series

Страница 1: ...on of the zero point no further referencing necessary Permanent retention of all data and settings Reserve energy up to 3 years AUTO POWER OFF function with adjustable switch on time Switch over for a...

Страница 2: ...4 5 3 Parameter settings 6 5 4 Parameter list 7 6 BATTERY CHANGE 8 7 MAGNETIC TAPE 9 7 1 Handling 9 7 2 Processing note for sticking 10 7 3 Resistance to chemicals of the magnetic tape 10 7 4 Stickin...

Страница 3: ...resistant against abrasion dust dirt and water protection class IP 67 The user must provide and guarantee for a suitable mechanical guiding system to guide the sensor and keep it along the whole move...

Страница 4: ...ting direction is reversible in parameter P01 see chapter 5 4 5 1 2 Referencing Setting the zero point A new AZ16E unit shows always the absolute value of the magnetic tape and should be calibrated to...

Страница 5: ...et By pressing F Set together the display sets to the reference value deposited in register P09 Switch back from the sleep mode F The unit switches into the sleep mode after completion of the adjustab...

Страница 6: ...four times LSB 0 001 Inch F 1 Press button F for 3 seconds P01 Parameter 01 appears in the display window Set 3 Select the desired decade by pressing Set Incr Abs 4 Adjust the desired value by using t...

Страница 7: ...e direction disabled Arrow symbol for positive direction enabled 0 1 LCD in standby mode disabled LCD in standby mode enabled Display OFF and battery condition P 03 Decimal place default setting 1 X 0...

Страница 8: ...999999 9 mm 9999 999 Inch 9999 999 Inch P 99 Indicates the software version 1 21 SW V1 21 P 08 Position scaling factor 0 001 9 999 the position value is multiplied by the factor adjusted here default...

Страница 9: ...tape from extreme external magnetic influences To reach a complete adhesion between the several materials a special sticky tape is used Pos 2 Pos 4 Pos 6 Pos 1 Covering band Pos 2 Sticky tape Pos 3 Ma...

Страница 10: ...p proximately 1 year Acetone Gasoline Acetic acid 30 Olein acid Acetylene Steam Acetic acid pure Acetic acid Sea water Ammonia Acetic acid 20 Isopropyl ether Stearic acid 70 C anhydrous Kerosene Stron...

Страница 11: ...8 mm with battery condition signs and symbols Keypad Membrane keypad Operating temperature 5 50 C Stock temperature 0 70 C Humidity Not condensing max 80 Altitude max 2000 m above sea level Protectio...

Страница 12: ...12 9 Dimensions 9 1 Display Unit Panel cut out B x H 93 x 67 mm 96 72 63 9 92 6 27 43 34 5 5 37 Install depth 66 minus 9 mm plug can be bended 34...

Страница 13: ...unting into a panel serves 2 small mount ing plates with grub screws included in the deliv ery see image right The unit must be pushed from the front into the cut out and fixed from the rear by the gr...

Страница 14: ...tc 0 fixed cable output 1 plugable by RJ45 connector standard 03 0 Options 1 one internal size C battery standard 2 two internal size AA batteries 3 external battery case Sensor cable lenght max 20 m...

Страница 15: ...ore we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is one calendar year...

Отзывы: