8
Metrological Features
141
instead of "calculated" to "Constant value". The range of the constant entered is not limited.
Fig. 68 Setting the constant compressibility value for calculating C (SW Compass)
8.4 Volumes Measurement and Calculation
To measure and calculate volumes, the following counters are used for each channel in the
device:
V
m
- Volume counter under the measurement conditions (primary volume)
V
c
- Corrected volume under the measurement conditions (volume corrected
based on the correction profile of the meter)
V
- Volume V
m
or V
c
Vs
- Operating volume counter at error conditions (substitute primary
volume)
Vb
- Volume counter at base conditions
Vbs - Base volume counter at error conditions
8.4.1 Calculation of conversion number C for volume conversion
As stated in paragraph 7.9.1, the following relation applies to the calculation of volume under
basic conditions:
V
b
= V * C
The following applies to the conversion number:
C = p *
T
b
* 1
p
b
(t + 273.15)
K
The conversion number C depends on the degree of compressibility of the gas K, the reference
conditions (pb, Tb), the gas pressure p and the gas temperature t.
Содержание DATCOM
Страница 38: ...3 Technical Parameters 36 ...
Страница 45: ...5 Installation and Commissioning 43 5 1 2 ELCORplus corrector Fig 2 ELCORplus device dimensions ...
Страница 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Страница 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Страница 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Страница 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Страница 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Страница 139: ...7 Technical Description of the Device 137 Fig 65 Volume and energy calculations calculation scheme ...
Страница 159: ...10 Communication with the Device 157 packet ...
Страница 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Страница 175: ...12 Accessories 173 Fig 79 ELCOR example of use of external modules Fig 80 ELCOR example of use of external modules ...
Страница 211: ...Appendix 2 ELCORplus version for Zone 2 209 Fig 86 Block diagram ELCORplus for zone 2 with ext 230V power supply ...
Страница 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Страница 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Страница 216: ...Appendix 3 Compass Data Export 214 ...
Страница 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...