Installation
Sorensen DCS Series 3kW Supplies
2.4.3 Ventilation
The DCS system supply is fan-cooled, so it requires space on the sides for the ventilation inlets
and space at the rear for the ventilation exhaust. The following temperature ranges apply for the
best results when operating or storing the unit.
Operating Ambient Temperature
0 to 50°C no derating. From 50 to 70°C, derate 2% per °C
Storage Temperature Range
-55 to +85° C
2.4.4
AC Input Power
Section 2.5 AC Input Power Connection
gives instructions for making connections to either
single phase or three phase AC power sources. Order replacement AC input connectors and
contacts using the following part numbers.
Housing
AMP 641685-1
Chassis-Mounted Parts
Contact Pins
AMP 350821-1
Connector Housing
AMP 643267-2
Mating Connector Parts
Contact Pins
AMP 350821-1
2.5
2.5.1
AC Input Power Connection
Before you can use the DCS system supply, you must determine your AC input power
requirements and assemble an appropriate line cord and connector. The power supply is
shipped with a kit of connector and strain relief parts which you assemble using the procedures
in this section.
AC Input Power Requirements
This supply may be operated from either a single phase or a three phase AC power source. The
specifications for input voltage, current, and frequency are listed below.
AC Input Voltage Range
Maximum Input Current
Frequency
200-250 Vac Single Phase
20 Arms
47-63 Hz
190-250 Vac Three Phase
14 Arms
47-63 Hz
CAUTION
The maximum output power must be limited to 2500 Watts when the power
supply is used with a single phase input to avoid tripping the power
supply's input circuit breaker.
2-4