1-1
SECTION 1 – GENERAL DESCRIPTION
1.1 INTRODUCTION
The Elgar Models SW 10500, SW 15750, and SW 21000 provide the same high quality
power source as the SW 5250A, but at higher power levels. These systems are comprised
of one master chassis, one or more slave chassis, a power distribution (PDU) chassis, and
an optional input power line filter (required for CE mark).
This parallel installation manual is to be used in conjunction with the operating manual for
the SmartWave Switching Amplifier Model SW 5250A, referred to as the main manual.
The following specifications for the SW 10500, SW 15750, and SW 21000 are identical to
the SW 5250A unless otherwise noted.
1.2 INPUT SPECIFICATIONS
Input Power Ranges:
Factory configured 187 to 264 VRMS, 3 phase L-L (3 wire), or
342 to 457 VRMS, 3 phase L-L (4 wire). A chassis ground is also required for safety.
115/230 VRMS selectable, single phase, for power distribution unit (PDU).
Input Power Factor:
.6 with USA rectifier, .35 with international rectifier,
.99 with input PFC option.
Input Frequency Range:
47 to 63 Hz.
Efficiency:
70%, minimum, at full load.
Ride Through:
3 mSEC, minimum, 10 mSEC minimum, with PFC option.
1.3 OUTPUT SPECIFICATIONS–NORMAL OPERATION MODE
Power Factor of Load:
0 lagging to 0 leading
AC or DC Output Voltage:
0 to 156 VRMS L-N range 1; 0 to 312 VRMS L-N range 2.
Output Current Per Phase SW 10500:
26A to135V in 156V range, derates linearly to
22.4A @ 156V; 13A to 270V in 312V range, derates linearly to 11.2A @ 312V.
Output Current Per Phase SW 15750:
39A to 135V in 156V range, derates linearly to
33.6A @ 156V; 19.5A to 270V in 312V range, derates linearly to 16.8A @ 312V.
Содержание SmartWave SW 10500
Страница 2: ......
Страница 19: ...SECTION 2 INSTALLATION SW 10500 15750 21000 2 8 FIGURE 2 2 CABINET FRONT VIEW SW 15750 Slide Mounting ...
Страница 20: ...SW 10500 15750 21000 SECTION 2 INSTALLATION 2 9 FIGURE 2 3 CABINET FRONT VIEW SW 21000 Slide Mounting ...
Страница 21: ...SECTION 2 INSTALLATION SW 10500 15750 21000 2 10 FIGURE 2 4 CABINET SIDE VIEW SW 15750 Slide Mounting ...
Страница 22: ...SW 10500 15750 21000 SECTION 2 INSTALLATION 2 11 FIGURE 2 5 CABINET SIDE VIEW SW 21000 Slide Mounting ...
Страница 23: ...SECTION 2 INSTALLATION SW 10500 15750 21000 2 12 FIGURE 2 6 CABINET SIDE VIEW SW 15750 L Bracket Mounting ...
Страница 24: ...SW 10500 15750 21000 SECTION 2 INSTALLATION 2 13 FIGURE 2 7 CABINET SIDE VIEW SW 21000 L Bracket Mounting ...
Страница 25: ...SECTION 2 INSTALLATION SW 10500 15750 21000 2 14 FIGURE 2 8 CABINET REAR VIEW SW 10500 Slide Mounting ...
Страница 26: ...SW 10500 15750 21000 SECTION 2 INSTALLATION 2 15 FIGURE 2 9 CABINET REAR VIEW SW 15750 Slide Mounting ...
Страница 35: ...SECTION 3 OPERATION SW 10500 15750 21000 3 2 This page intentionally left blank ...