ELGA MEDICA Pro 120 Скачать руководство пользователя страница 34

MEDICA Pro 30/60/120 US Operator Manual 

ELGA

 

 

Page 32

 

MEDICA Pro 30/60/120 US MANU40594 Version 1 - 07/14 

11. 

WARRANTY/CONDITIONS OF 
SALE 

ELGA LabWater is a trading name of VWS (UK) Ltd. 

General Limited Warranty 

VWS  (UK)  Ltd.  warrants  the  products  manufactured  by  it 
against  defects  in  materials  and  workmanship  when  used 
in  accordance  with  applicable  instructions  for  a  period  of 
one year from the date of shipment for the products. VWS 
(UK) Ltd. MAKES NO OTHER WARRANTY, EXPRESSED 
OR 

IMPLIED. 

THERE 

IS 

NO 

WARRANTY 

OF 

MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR 
PURPOSE.  The  warranty  provided  herein  and  the  data, 
specifications  and  descriptions  of  the  VWS  (UK)  Ltd. 
products appearing in VWS (UK) Ltd. published catalogues 
and  product  literature  may  not  be  altered  except  by 
express  written  agreement  signed  by  an  officer  of  VWS 
(UK)  Ltd.  Representations,  oral  or  written,  which  are 
inconsistent with this warranty or such publications are not 
authorized and, if given, should not be relied upon. 

In  the  event  of  a  breach  of  the  foregoing  warranty,  VWS 
(UK) Ltd. sole obligation shall be to repair or replace, at its 
option,  any  product  or  part  thereof  that  proves  to  be 
defective  in  materials  or  workmanship  within  the  warranty 
period,  provided  the  customer  notifies  VWS  (UK)  Ltd. 
promptly  of  any  such  defect.  The  exclusive  remedy 
provided  herein  shall  not  be  deemed  to  have  failed  of  its 
essential purpose so long  as VWS (UK) Ltd. is willing and 
able to repair or replace any nonconforming VWS (UK) Ltd. 
product  or  part.  VWS  (UK)  shall  not  be  liable  for 
consequential,  incidental,  special  or  any  other  indirect 
damages resulting from economic loss or property damage 
sustained by any customer from the use of its products. 

VWS (UK) Ltd. Warranty 

VWS  (UK)  Ltd.  warrants  the  water  systems  manufactured 
by 

it, 

BUT 

EXCLUDING 

MEMBRANES 

AND 

PURIFICATION  PACKS,  against  defects  in  materials  and 
workmanship when used in accordance with the applicable 
instructions  and  within  the  operating  conditions  specified 
for the systems for a period of one year from the earlier of: 

a) 

the date of installation, or 

b) 

the 120th day following the date of shipment. 

VWS  (UK)  LTD.  MAKES  NO  OTHER  WARRANTY, 
EXPRESSED  OR  IMPLIED.  THERE  IS  NO  WARRANTY 
OF 

MERCHANTABILITY 

OR 

FITNESS 

FOR 

PARTICULAR  PURPOSE.  The  warranty  provided  herein 
and  the  data,  specifications  and  descriptions  of  the  VWS 
(UK)  Ltd.  systems  appearing  in  VWS  (UK)  Ltd.  published 
catalogues  and  product  literature  may  not  be  altered 
except  by  express  written  agreement  signed  by  an  officer 
VWS (UK) Ltd. Representations,  oral  or  written, which are 
inconsistent with this warranty or such publications are not 
authorised and, if given, should not be relied upon. 

In  the  event  of  a  breach  of  the  foregoing  warranty,  VWS 
(UK) Ltd. sole obligation shall be to repair or replace, at its 
option,  any  product  or  part  thereof  that  proves  to  be 

Содержание MEDICA Pro 120

Страница 1: ...MEDICA Pro 30 60 120 US Operator Manual...

Страница 2: ......

Страница 3: ...be reproduced or used except as authorized by contract or other written permission from VWS Ltd The copyright and all restrictions on reproduction and use apply to all media in which this information...

Страница 4: ...rvice Operational day screen 030 17 4 2 Continuous Recirculation 24 7 screen 029 17 5 MAINTENANCE 18 5 1 Replacing Composite Vent Filter L136 18 5 2 Replacing Medpure L1 LC174 18 5 3 Replacing Ultra M...

Страница 5: ...om for further information 1 3 HEALTH AND SAFETY NOTES WARNING WARNINGS ARE GIVEN WHERE FAILING TO OBSERVE THE INSTRUCTIONS COULD RESULT IN INJURY OR FATALITY CAUTION Cautions are given where failure...

Страница 6: ...ntrol of Substances Hazardous to Health COSHH Material safety data sheets covering the various replaceable components are available upon request Contact your local ELGA LabWater distributor 1 8 Consum...

Страница 7: ...at allows the unit to be quickly installed and commissioned It is recommended that a trained ELGA representative carry out the installation of the product 2 2 Commissioning The unit is supplied with t...

Страница 8: ...CA control panel has a range of control icons General icons are as follows Further icons are described in the appropriate sections a complete listing is included in Section 11 BUTTON ICON Function PRO...

Страница 9: ...t time after completing the commissioning routine the following steps should be carried out to set up your choices Note Your choices can be changed and implemented during normal operation It is not ne...

Страница 10: ...date OR PRESS to proceed to step 4 2 PRESS and HOLD to increase or to decrease day 3 PRESS to step cursor onto month 4 PRESS to increase or to decrease month 5 PRESS to step cursor onto year 6 PRESS t...

Страница 11: ...nge mode psi or bar OR PRESS TICK to proceed to step 7 2 PRESS TICK Step 7 Water purity unit setting screen 023 This screen allows preferred displayed units of water purity to be set to either M cm or...

Страница 12: ...s screen is used to select the value at which the product water purity alarm will activate The alarm does not stop the unit and will automatically reset if the purity level recovers 1 PRESS to select...

Страница 13: ...lar circumstances or when demand for water fluctuates CAUTION During long periods of continuous operation and low usage the water temperature will rise It is recommended that this function is only use...

Страница 14: ...highlight box 1 Monday enabled OR PRESS to step to box 2 Note A highlighted box indicates that the unit will be operational on that day between the times set in step 14 3 REPEAT step 15 item 2 to sele...

Страница 15: ...he conductivity of the permeate is compared to that of the feedwater Enter the feedwater conductivity to obtain an accurate measurement 1 PRESS to reduce the value to the correct reading 2 PRESS to ac...

Страница 16: ...tion 4 REPEAT instruction 2 and 3 until all User keys are registered maximum of 6 users 5 PRESS to complete settings Step 22 Programming of Sanitization Keys screen 038 Sanitization Keys are required...

Страница 17: ...OR PRESS to accept replacement date and proceed to CVF Reminder 2 PRESS to confirm that resetting is required OR PRESS to abort reset 3 PRESS Step 3 Composite Vent filter CVF replacement date 1 PRESS...

Страница 18: ...Step 6 UMF replacement date 1 PRESS button to reset UMF replacement date OR PRESS to accept replacement date and proceed to Sanitization reminder 2 PRESS confirm that resetting is required OR PRESS to...

Страница 19: ...to override this mode by PRESSING During the sleep period the unit will run in intermittent recirculation 10 minutes every two hours to maintain water purity around the distribution loop 4 2 Continuo...

Страница 20: ...FF and isolate power 2 OPEN front doors and locate CVF 3 UNSCREW old CVF and discard 4 UNPACK new CVF 5 WRITE the installation date on the label of the filter for future reference 6 INSTALL filter 7 S...

Страница 21: ...ater purity 5 3 Replacing Ultra Microfilter LC109 The Ultra Microfilter UMF should be replaced in the following circumstances When indicated by the consumable alarm After a maximum of 12 months use Pr...

Страница 22: ...ing spring clips from top and bottom of the lamp assembly 6 REMOVE electrical connectors from top and bottom and take lamp from housing WARNING IT IS STRONGLY RECOMMENDED THAT DURING THE HANDLING OF T...

Страница 23: ...ocess is OFF and ISOLATE power 2 OPEN front doors 3 LOCATE Protek 4 Remove lid from break tank and RELEASE any residual system pressure by OPERATING float valve 5 TWIST to RELEASE clip and OPEN retain...

Страница 24: ...et and outlet tubing from the E cartridge 5 REMOVE used cartridge from clip and discard in accordance with local regulations 6 TAKE new cartridge 7 REMOVE sealing plugs from inlet and outlet ports 8 L...

Страница 25: ...al growth will usually be lower with clean feed water well maintained pre treatment low temperatures and heavy usage WARNING ALWAYS WEAR RUBBER GLOVES APRON AND FACEMASK DO NOT BREATHE FUMES OR ALLOW...

Страница 26: ...rsion 1 07 14 Enter RO sanitization 5 PRESS to enter RO sanitization 6 UNSCREW the large white lid on the left of the unit 7 ADD 50ml of Minncare Cold Sterilant 8 REPLACE lid Confirmation sanitiant is...

Страница 27: ...missed then the system will automatically progress to the next step but the effectiveness of the sterilant may be reduced 14 PRESS the process button Once the step within the sanitization is complete...

Страница 28: ...ic cover 3 7 Open valve 3 8 Close valve 3 when there is no requirement for purified water 9 Monitor water purity independently or install new Medpure L1 cartridges to guarantee water purity 7 2 Emerge...

Страница 29: ...a supply purity of 1M at the analyzer may be calculated as follows Single Pack Time between pack changes 120 000 Conductivity of mains water x Water consumption of analyzer l hr Example Mains water co...

Страница 30: ...high 50 C Contact Technical support 672 94 Recirc loop over temperature PRESS mute to silence alarm Water temperature is unacceptably high 50 C Contact Technical support 93 LC175 LC177 Protek L1 inco...

Страница 31: ...DESCRIPTION Accept User Recognition Key Auto restart Locked Scroll back Menu Step back Mute alarm Bell Night Standby Option OFF Calibration point Option ON Cancel Output Clock Recirculate Date Reset D...

Страница 32: ...or L2 20 Backwashable media filter with a minimum flow rate of 20l min Iron manganese Fe Mn ppm 0 1 Protek L1 or L2 0 1 Back washable pre filter Organics TOC ppm C 3 Protek L1 or L2 3 Cylinder of carb...

Страница 33: ...y Features Power fail safe Water temperature alarm Water purity alarm Leak detection alarm Access restricted by User Recognition key Low voltage control circuit 24 V dc Visual alarms Audible alarms Ou...

Страница 34: ...ided herein shall not be deemed to have failed of its essential purpose so long as VWS UK Ltd is willing and able to repair or replace any nonconforming VWS UK Ltd product or part VWS UK shall not be...

Страница 35: ...anufactured by companies other than VWS UK Ltd or its affiliates Non VWS UK Ltd products are covered by the warranty if any extended by the Product manufacturer VWS UK Ltd hereby assigns to the purcha...

Страница 36: ...P14 3BY UK Tel 44 0 203 567 7300 Fax 44 0 203 567 7205 E mail techsupport elgalabwater com For the address of your nearest ELGA LabWater Sales and Service office visit the country list on our website...

Отзывы: