background image

OPTIMA SL255

Digital entry phone panels 

OPTIMA SL255

Installation and software manual for fitters

V.3.411

 Rev. 14

© 2016  ELFON

Содержание OPTIMA SL255

Страница 1: ...OPTIMA SL255 Digital entry phone panels OPTIMA SL255 Installation and software manual for fitters V 3 411 Rev 14 2016 ELFON...

Страница 2: ...2...

Страница 3: ...rization test 25 Lock test 26 Relay test 26 Communication test 26 Activate installation mode 27 5 1 3 Firmware Version 27 5 2 Access control 28 5 2 1 Service Code 28 5 2 2 Service RFID tags 28 5 2 3 C...

Страница 4: ...g 35 Auxiliary unlocking 35 Auxiliary unlocking time 35 Breakdown procedure 35 5 4 3 Relay settings 36 Synchronize with lock 36 5 4 4 General unlocking time 37 5 4 5 General RFID tags 37 5 4 6 Miscell...

Страница 5: ...n multi entry system 46 7 Safety principles during installation and operation 50 8 Troubleshooting 52 Illustrations index Figure 1 Panel terminals 9 Figure 2 Audio system single entry system 11 Figure...

Страница 6: ...try audio system 49 Figure 21 Multi entry audio system with OP H4 module 50 Figure 22 Data line connection in multi entry system 50 Figure 23 Multi entry video system 51 Figure 24 Video line and data...

Страница 7: ...of the OPTIMA series panels benefits integrated electronics all necessary elements of the system in the outdoor panel clear highlighted liquid crystal display comfortable illuminated vandal resistant...

Страница 8: ...supply the panel use a power supply of output voltage within the range 12 15VAC and current 2A min 20VA handsets with the digital entry phone system it is recommended to use Elfon OP U7 hand sets or e...

Страница 9: ...le to extent the distance to 70 m using the cable AWG17 AWG Cross section mm2 Maximum distance m 17 1 04 10 16 1 31 15 15 1 65 20 14 2 08 30 13 2 62 50 Table 3 Length of supply cables with 14 VAC supp...

Страница 10: ...tion In the audio system it is possible to establish voice connection between the panel and handset in flat To make the handsets connection use any two conductor cable of conductor cross section 0 5 m...

Страница 11: ...11 Figure 2 Audio system single entry system...

Страница 12: ...itors Correct configuration of the system necessitates connecting two pairs of cables to each of the used distributors OP VP4 audio line and video line It is recommended to use telephone twisted pair...

Страница 13: ...Figure 5 Example of video system with OP VR module and 2 videomonitors OP VM 13 Figure 4 Video system single entry system...

Страница 14: ...s own address tag in the panel address field 3 To do that loosen the locking bolt in the back part of the panel plastic cover in hole identified BS glass lock figure 7 Then depressing left part of the...

Страница 15: ...0 operate as arrows left up right down and keys identified with and confirm or cancel the selection Figures 9 10 present keyboard and functions of keys in the mentioned modes of operation 4 2 Initial...

Страница 16: ...rent code 4 3 Establishing a connection To establish a connection depending on the set option in menu 1 using the keyboard select flat number with which you want to connect and confirm with the key 5...

Страница 17: ...the entry panel from the keyboard select CODE statement appears on the screen Then enter flat number opening code and confirm by key Eg 123 which code is 5678 select from the keyboard 1235678 for fla...

Страница 18: ...12345678 Alternatively if a service RFID tag exists in the system the setting menu may be entered pressing the key four times and then placing RFID tag to the reader9 9 Applies to Optima SL255R Optima...

Страница 19: ...s Electric Lock Buzz Magnetic Lock Mode Unlocking Time Unlocking by General Code Unlocking by General RFID Tag Unlocking by Auxilliary Input Auxilliary Input Unlocking Time Breakdown Procedure Relay S...

Страница 20: ...ual Settings user access Enable Disable Edition Ring and Talking Ring Tone Ring Loudness Ringing Time Handset As Door Ring Electrical Lock Unlocking Unlocking F Handset Unlocking by RFID Tag Unlocking...

Страница 21: ...in the handset Number set using this method is a physical address of a handset Flat number consists of 4 digits selected on the panel keyboard by user Optima panels have wide options concerning mappin...

Страница 22: ...en all of the addresses are occupied device will prompt RANGE FULL Entering a number from the range will call the corresponding handset and entering a number outside the range will be signalled with a...

Страница 23: ...lats numbered first storey 1001 1002 1003 1004 1005 1006 1007 second storey 2001 2002 2003 2004 2005 2006 2007 third storey 3001 3002 3003 3004 3005 3006 3007 To limit the calling to the presented num...

Страница 24: ...anges is Assignment NO HS where No flat number HS handset physical number that gives currently added numbers and corresponding physical addresses to be set in the handsets The feature allows editing i...

Страница 25: ...r such handsets is added To use this option Enter the menu Settings code Select Service programs confirm with Select Handsets test confirm with Select Handsets picked up confirm with Panel will check...

Страница 26: ...s the relay Operation of additional relay NO and CON outputs can be checked using a test without codes To start the test Enter the menu Settings code Select Service programs confirm with Select Relay...

Страница 27: ...panel starts searching the whole existing range of handsets numeration see clause 5 1 2 Wait for short sound signal confirming handset recognition After the signal put down the receiver after a while...

Страница 28: ...with When SAVE message appears confirm with Factory service code always starts with four digit prefix 1131 To provide compatibility it is recommended that the new code maintains the prefix 5 2 2 Servi...

Страница 29: ...nfirm with Select Access control confirm with Select Check RF tag Message appears APPLY RF TAG each tag application causes that information that concerns the tag is displayed To leave the RF tags chec...

Страница 30: ...selected number and confirm with Confirm with Confirm again with Using this function new general opening codes will be generated general and individual according to the given table number 5 2 7 Change...

Страница 31: ...er the menu Settings code Select Default settings confirm with Select Default individual settings confirm with Confirm again with 5 3 4 General default codes Restores general factory codes it is a tab...

Страница 32: ...lking time Enter the menu Settings code Select General settings confirm with Select Talking settings confirm with Select Talking time confirm with Screen informing about current setting appears NOW X...

Страница 33: ...ceiver and attempt to establish connection After that the panel returns to standstill This time can be set within 1 99 s Default set value is 15 s To change the time Enter the menu Settings code Selec...

Страница 34: ...lock mode confirm with Message informing about current setting appears ENB or DIS to change press Message appears SWITCH TO and using the arrows up or down select the required setting and confirm wit...

Страница 35: ...ectric lock settings confirm with Select Auxiliary unlocking confirm with Message informing about current setting appears ENB or DIS to change press Message appears SWITCH TO and using the arrows up o...

Страница 36: ...ectric lock are copied to relay settings thus relay acts identically as the electric lock Upon deactivation of this option option applying to relay are restored Unlocking time see electric lock settin...

Страница 37: ...e Select General settings confirm with Select General unlocking codes confirm with Using arrows select the code to be changed confirm with The message appears SWITCH TO Enter new general code and conf...

Страница 38: ...onfirm with Select Keyboard multi tone confirm with Message informing about current setting appears ENB or DIS to change press Message appears SWITCH TO and using the arrows up or down select the requ...

Страница 39: ...TO and using the arrows up or down select the required setting and confirm with 5 4 7 Tenants list buttons Mapping 12 buttons of OP J4 modules to physical addresses of handsets Optima panels allow co...

Страница 40: ...the loudness level within the range 1 do 3 Enter the menu Settings code Select Individual settings confirm with Select Ring and talking confirm with Select Ring loudness confirm with Select flat numbe...

Страница 41: ...s Message appears SWITCH TO and using the arrows up or down select the required setting and confirm with Screen SAVE appears using the arrows up or down it s possible to select SAVE FOR ALL USERS or S...

Страница 42: ...pears SWITCH TO and using the arrows up or down select the required setting and confirm with Screen SAVE appears using the arrows up or down it s possible to select SAVE FOR ALL USERS or SAVE FOR GROU...

Страница 43: ...appears SWITCH TO and using the arrows up or down select the required setting and confirm with Screen SAVE appears using the arrows up or down it s possible to select SAVE FOR ALL USERS or SAVE FOR G...

Страница 44: ...idual flats is also possible from the PC level using Optima PC software 5 5 6 Turn off handset Turns the handset off panel does not dial etc Enter the menu Settings code Select Individual settings con...

Страница 45: ...ect flat number and confirm with Screen informing about current setting appears Enable edit Disab edit to change press Message appears ENABLE EDITION or DISABLE EDITION and using the arrows up or down...

Страница 46: ...panels OPTIMA SL255 are adapted to operate in multi entry system It is possible to extend the system to operate maximum 4 entries Handset line is connected in parallel to LU and GND terminals of each...

Страница 47: ...eral settings Outdoor panel settings Multi entry settings the option Two panels or OP H4 mode In each panel operating in the system the Multi entry mode must be set to the same settings 47 Figure 19 T...

Страница 48: ...48 Figure 21 Multi entry audio system with OP H4 module Figure 22 Data line connection in multi entry system...

Страница 49: ...enable switching the output signal of video distributor depending on which panel the dialling is performed from switcher OP VP4 and communication module OP H4 are equipped with communication line PK...

Страница 50: ...y etc Avoid short circuits between the panel terminals Do not expose the panel to chemical substances that could react with metals plastics etc Apply general safety procedures during installation Havi...

Страница 51: ...uxiliary unlocking time 4s breakdown procedure ENB o outdoor panel settings dialling after confirmation DIS keyboard sound ENB keyboard multi tone DIS OPH4 mode enable for OP SL255 OP SL255R disable f...

Страница 52: ...m Contact service facility Panel displays the message ERR KEYB Keyboard defective Contact service facility Panel displays the message SHORT LINE Shorted handsets line Eliminate the short circuit Note...

Страница 53: ...on Communication test In case of mode OP H4 mode check whether the communication module channels to which the panels are connected are activated see OP H4 four channel communication module installatio...

Страница 54: ...14VAC 2 0A OPTIMA SL255RC OP H4 OP J4 OP LPM AC20 AC20 or AC40 14VAC 1 4A OPTIMA SL255RC OP H4 OP EL OP LPM AC20 AC20 or AC40 14VAC 2 0A OPTIMA SL255RC OP H4 OP VP4 OP LPM AC20 AC20 or AC40 14VAC 1 5A...

Страница 55: ...try code Entry code Flat no Flat no Entry code Entry code Flat no Flat no Entry code Entry code Flat no Flat no Entry code Entry code Flat no Flat no Entry code Entry code Flat no Flat no Entry code E...

Страница 56: ...umulators it is forbidden to dispose waste identified with the symbol of crossed out trash can with other household waste User indenting to dispose the product is obligated to deliver batteries and wa...