Page 10
Guardian Bridge Advanced User Manual
Compatible Command Classes
BY ELEXA
Command Class
Notes
COMMAND_CLASS_VERSION V2 (86)
Returned Value: 03 04 3D 01 01 01 00
Z-Wave Library Type: 03
(Enhanced Slave)
Protocol Version: 04 3D
Protocol Sub-Version: 01 01
Application Version: 01
Application Sub-Version: 00
COMMAND_CLASS_BASIC V1 (20)
-
COMMAND_CLASS_SWITCH_BINARY V1 (25)
Binary Switch commands will open/close the valve. Reports are used
to communicate valve opening/closing
Valve Open: FF
Valve Closed: 00
COMMAND_CLASS_SENSOR_MULTILEVEL V11 (31)
The Multilevel CC is used to communicate the temperature recorded
by the Valve Controller in the Guardian system. This is only reported
to association group 3.
Returned Value: 01 XX XX
Sensor Type
01 (Temperature)
Precision/Scale/Size (Celsius) 01 (Precision = 000; Scale = 00; Size =
001)
Precision/Scale/Size (Farenheit) 01 (Precision = 000; Scale = 00; Size
= 001)
Sensor Data
00 ~ FF (-125 ~ 125 in Degrees Fahrenheit or Celsius)
COMMAND_CLASS_MULTI_CHANNEL V4 (60)
The Multi Channel Command Class is used to distinguish commands
to/from the Valve Controller endpoint (endpoint 1) and the Leak De-
tector endpoint (endpoint 2).
COMMAND_CLASS_ASSOCIATION V2 (85)
Group 1
Group 1 is the “Lifeline” group, which can hold five devices.
COMMAND_CLASS_ASSOCIATION_GRP_INFO V3 (59)
-
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
(72)
Returned Value: 02 1F 01 02 03 04
Manufacturer ID: 02 1F
Product Type: 01 02
Product ID: 03 04
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 (5A)
-
COMMAND_CLASS_POWERLEVEL V1 (73)
-
COMMAND_CLASS_SUPERVISION V1 (6C)
-
COMMAND_CLASS_FIRMWARE_UPDATE_MD V4 (7A)
-
COMMAND_CLASS_CONFIGURATION V1 (70)
See ““Configuration” Command Class Parameters”
Compatible Command Classes