C. Volume / Mute Control: 

Volume control is setup by default in 

“Global” mode meaning volume/mute can be adjusted from any node of 
the system and all nodes share the same global settings.  Other volume 
modes can be setup using the parameter page.

Volume buttons on the Tx and Rx will increase/decrease the volume audio 
level by 1dB per button press for a total of 70 steps.  Pressing and holding 
a volume button will ramp the volume quickly.  Maximum volume is 0dB 
and minimum volume is -70dB.  NOTE:  Volume settings are stored and 
recalled on reboots. (Normal Default Setting: Max for both channels)

D. RF Mating: 

A Tx node and an Rx node will not connect to each 

other unless they have the same 16 bit Mating ID stored in their 
respective parameter pages.  Out of the box, the MR evaluation kit is 
already pre-mated.  RF Mating is the procedure of matching (or re-
matching) the 16 bit Mating ID of 2 or more nodes. 

RF Mating is usually initiated by pressing and holding the RF Mating 
button on the Tx for more than 3 seconds until the Tx bond LED flashes 
quickly.  The Tx will then generate a 16 bit random number to use for the 
new Mating ID.  The Tx then attempts to mate with Rx nodes.  Rx nodes 
briefly enter RF mating mode every time they are powered on, so power 
must be cycled on each Rx node that you want mated to the Tx.  RF 
Mating has a default timeout of 1 minute.  If the Tx does not find any Rx 
nodes before the timeout it will terminate RF Mating mode and revert 
back to the previous Mating ID.  If successful mating occurs before timing 
out, the number of Rx nodes that mate to the Tx will define the new 
topology after RF Mating has timed out or completed (i.e., 2-Node or 3-
Node).

E. Audio Level Standby: 

The Audio Level Standby Feature is 

implemented on the TX node.  This feature is implemented in order to 
reduce power consumption when the audio level drops below a 
particular threshold.  When the audio level drops below this threshold for 
a predetermined amount of time, the Tx sends a sleep command to the 
Rx.  The Rx will then enter a low power sleep mode and will wait for the 
audio level to rise above the threshold. (Normal Default Setting: 78 
seconds)

F. Reset Button: 

Pressing the Reset button will reset the entire 

module. This button is sometimes useful when downloading new 
firmware.

G. XPD Port Interface:

The XInC Programming and Debugging (XPD) port is used to download 
firmware hex files to the MR-284 module, using an XPD Programming 
Module (available from Eleven Engineering).

For more information regarding the XPD Port, XPD Module, and the 
procedure for programming modules refer to the document 

“Downloading Firmware to XInC Processors” (Available from Eleven 
Engineering).

H. Two Wire Serial Interface (TWSI): 

The MR system incorporates 

an I2C compatible two wire control interface, used to configure the system’s 
optional settings.  The TWSI also provides developers with a method to transfer 
data over the wireless link.

i) TWSI controls: 

MR settings (buffer size, audio mode, mating ID, 

etc.) may be programmed via TWSI; however, when these settings are 
adjusted most will trigger a system reset.  Some settings meant for 
real time controls (volume and mute control, etc.) can be set live 
without triggering a reset.  

ii) Pass-through TWSI data channel: 

User data sent into the 

audio Tx is directly output “as-is” from the audio Rx and similarly for 
the reverse direction (Rx to Tx). 

NOTE: When using a custom external audio chip, fundamental firmware 
modifications may be required to configure the chip registers.  These changes 
can not be done with the TWSI.

I. Parameter Pages: 

The MR system comes pre-loaded with a parameter 

page that configures the default functionality of the system.  Some of the 
commonly changed registers are listed below.

Addr 00/01

Mating ID number

Addr 02

RF Configuration (RF mating, Static ID, Dynamic Mating)

Addr 03

Buffer Size (Latency)

Addr 06

General Configuration (TWSI Mode, TWSI Interrupt Enabled, Sleep, Noise 
Gate)

Addr 0E

Audio Configuration (Stereo, Right Channel, Left Channel, Local/Global 
Volume mode, l2S/Left-Justified mode)

MR-284 Evaluation Kit Operating Instructions

DO4711

MR

www.ElevenEngineering.com 

   

MR-284 Evaluation Kit Instructions 

 

         DO4711| 

2009.11.05

Page 2/4

Содержание MR-284

Страница 1: ... application firmware implements a number of useful user interface features such as LED blinking and push button volume control It also supports customizable settings which can be loaded into the modules over Two Wire Serial Interface TWSI or via the XPD programming interface These settings are stored in a Parameter Page which is a file stored in non volatile memory on the MR 284 module This secti...

Страница 2: ... command to the Rx The Rx will then enter a low power sleep mode and will wait for the audio level to rise above the threshold Normal Default Setting 78 seconds F Reset Button Pressing the Reset button will reset the entire module This button is sometimes useful when downloading new firmware G XPD Port Interface The XInC Programming and Debugging XPD port is used to download firmware hex files to ...

Страница 3: ...SD safe mounts Cables should be as far away as possible from equipment that can introduce noise into nodes i e CRT monitors AC Transformers etc Batteries can be used to eliminate 50 60Hz noise The antenna orientation shown is for audio testing A different antenna orientation may be better suited for maximum RF range performance To test multiple Rx Nodes test each Rx node with the Tx node Evaluatio...

Страница 4: ...ortant to overall RF range performance Layout of the testing space affects RF performance Reflections of the RF can cause interference Obstacles such as the tester s body walls and cubicles can affect the range wherever possible keep node antennas in line of sight Other RF devices operating in the 2 4GHz spectrum can affect the RF performance such as microwaves wireless routers and other equipment...

Отзывы: