Eletech EM34A Скачать руководство пользователя страница 6

Application Example

Automatic Playback on Power-up

1. Repeat continuously on power-up.

Intended Operation

- Play file #001 on power-up if switch #1 is closed.
- Play file #002 on power-up if switch #2 is closed.
.........
- Play file #004 on power-up if switch #4 is closed.
- If  more  than one  switch  is  closed,  play all  corresponding  files

sequentially.

- Repeat  the file(s)  until  power  is turned  off.

Required Text in MODE.TXT

RN

Notes

- If priority is  required, use DN instead  of RN. In this  case switch

#1 has the highest priority, switch  #2 has the second highest
priority, and switch  #8 has the lowest priority. If  more than one
switch is turned on, only the file for the switch of the highest
priority  will  be  played.

2. Repeat at intervals on power-up.

Intended Operation

- Same  as  the  example  above  but  play  files  at  fixed  intervals.
- Only  files  with  corresponding  switches  closed  will  play.

Required Text in MODE.TXT

RS
N001=F001,W06000
N002=F002,W06000
.....
N008=F008,W06000
END

Notes

- W06000 is a delay loop of 6000 x 0.1 second = 10 minutes, so

the file(s) will be played at an interval of 10 minutes, one file at a
time.

Application Example

Triggering with Normally Closed Switches & Sensors

1. Play when the switch/sensor opens, with no priorities.

Intended Operation

- Play file #001 when sensor #1 opens.
- Play file #002 when sensor #2 opens.
- Repeat the sound for as long as the sensor is open.
- If  multiple  sensors are  open  at  the  same  time, play  all  corre-

sponding  files  sequentially.

Required Text in MODE.TXT

RNO

Notes

- Unused inputs must be connected to the ground, as shown in

the  wiring  diagram.

2. Play when the switch/sensor opens, with priorities.

Intended Operation

- Same as the example above, but if multiple sensors are open at

the  same  time,  the  sensor  of  the  highest  priority  prevails.

Required Text in MODE.TXT

DNO

Notes

- The sensor connected to T1 has the highest priority, and the

sensor connected  to T8 has the  lowest priority.

3. Play when the switch/sensor opens, but don’t repeat.

Intended Operation

- Play file #001 when sensor #1 opens.
- Play file #002 when sensor #2 opens.
- Do not repeat the sound.

Required Text in MODE.TXT

DSB
N001=F001,J999
N002=F002,J999
H999=J999
END

Notes

- The system  will stay in the  “H999=J999” endless loop  for as

long as the sensor is open. The system will not respond to  other
sensors  until  this  one  is  closed.

EM34A / EM34A-R / EM34A-X  User’s Manual  

Page 6 of 6