background image

SHK attachment (haul chain) 
for D 170–250 and D 350 (with brake)

GB

Warning!

Important safety instructions!

Observe the following instructions.

Risk of injury due to electric shock.

The connections to the 230 V mains 

must

be made

by authorised specialist personnel.

SHK for D. 170-250 and D 350 (with brake)

1. Switch the mains power off and secure the device against being

turned on again unintentionally.

2. Open the motor terminal box.

3. Remove the motor cable from the motor terminal board.

4. Remove the blind screw connection* on the NHK housing.

This is on the bottom.

5. Remove the 4 x countersunk screws from the NHK housing.

6. Place the SHK attachment on the NHK housing and push it

forward until the flange is touching.

Note:

Ensure that the anti-rotation teeth* are at the bottom.

7. Fix the SHK housing with 4 countersunk screws M6x70 DIN 965

and 4 x toothed washers 6.4 DIN 6797.

Note:

It is 

essential

to check the function of the micro switch.

When the bearing bush is lowered (turn the chain wheel),
the NHK contact (see wiring diagram in the NHK
operating instructions) must be open.

8. Connect the motor cable to the motor terminal board.

9. Screw the terminal box cover down securely.

Note:

It is 

essential

to mount the shim ring 25x35x0.2 provided

between the KL safety piece and the chain guide.

The drive is now ready for operation!

Anti-rotation teeth*

T

erminal box cover

Blind screw connection*

Micro switch

Driving bush

Chain guide

SHK 350 attachment

KL safety piece

Shim ring 25x35x0.2

Rotor shaft

Brake

SHK housing

for D.. 170-250

for  D.. 350 (with brake)

T

oothed washer     

V 6.4 DIN 6797

M6x70 DIN 965

Countersunk screws

NHK housing

Rotor shaft

SHK housing

top

bottom