elero RolMotion M Скачать руководство пользователя страница 5

Removing and inserting the motor cable plug 

Delivery con-

dition 

Removing plug 

Inserting plug 

Fig. 4  Removing and inserting the motor cable plug 

5.3  Connection example for RolMotion M  

230 V / 50 Hz 

1 0 2

reseau electrique

L

N

PE

230V/50Hz

ver

t-j

aune

br

un

no

ir

ble

u

de volet

M

1~

1 0 2

rete

L

N

PE

230V/50Hz

ver

de

/g

ial

lo

m

ar

rone

ner

o

blu

M

1~

1 0 2

Netz

L

N

PE

230V/50Hz

gr

ün/

gel

b

br

aun

sc

hw

ar

z

bla

u

oder -taster

M

1~

1 0 2

power grid

L

N

PE

230V/50Hz

gr

ee

n/

Yel

low

br

own

bl

ac

k

blu

e

junction box

M

1~

boiter de

scatola di

derivatione

(3)

(2)

(1)

(3)

(2)

(1)

Fig. 5    Connection diagram RolMotion M 230 V / 50 Hz  

and cable assignment when using Hirschmann plug 

connection STAS-3 

Important 

The motor controls in the Open and Down/Closed travel 

directions must be locked against each other. 
A switching time of at least 0.5 seconds must be observed. 

5.4  Parallel circuit 

Important 

You can connect up to 3 (maximum) RolMotion M in 

parallel. Please note the maximum switching capacity of 

the control unit. 

However, the behaviour of the devices is not synchronous. 
Do not connect the RolMotion M drive in parallel with other 

drives (e.g. elero RolTop M). 

5.5  Commissioning 

Important 

The drive is in commissioning mode when delivered. 

 

The end positions must be adjusted using the 

elero

 

assembly cable (see Fig. 6). 

 

The assembly cable may only be connected to 

commission the drive and for adjustment operations 

1

2

3

5.5.1  Connection for assembly cable 

%ODX1HXWUDOOHLWHU

6FKZDU]

%UDXQ

*UQJHOE

HOHUR

HOHUR

:KLWHQHXWUDOFRQGXFWRU

%ODFN

5HG

*UHHQ

Fig. 6  Connection for assembly cable 

 

Switch on mains. 

 

You can now set the end positions with the 

elero

 

assembly cable. 

5.6  Setting the end positions 

Important 

To use travel profiles, the upper and lower end positions 

must first be set. 

First program the upper end position, 

then the lower end position. 

 

The end positions and the strain relief are set 
•  via the 

elero

 assembly cable (ensure correct connection 

according to chapter 5.5.1) 

5.6.1  Changing/deleting the end positions 

It is not possible to change or delete individual end 

positions. This is always done in pairs (upper and lower end 

position simultaneously). 
Before you can change or delete the end positions, the 

power supply must first be interrupted. 

After a brief disconnection from the power supply, the end 

positions can be deleted within 5 minutes. 

Changing/deleting the end positions 

Restore the power supply after the mains have been 

switched off. 

Starting from a central blind position, use the as-

sembly cable to simultaneously press both direction 

buttons [

UP 

▲]+[

DOWN/CLOSE 

▼], and hold them 

down until the drive briefly moves up and down. 

The end position settings have been deleted. 
The end positions may be readjusted. 

5.6.2  Four variants of end position settings 

Four different end position settings are possible. These can 

be clearly selected according to the technical requirements 

of the blind.

End position settings 

(4 variants) 

possible with 

Upper and lower end 

position freely adjustable 

Suspension spring, 

tapes, belt 

B

Fixed upper limit stop, 

lower end position freely 

adjustable 

T-straps, tapes, belt, 

limit plugs, angle 

bracket 

Fixed upper and 

lower limit stop 

Anti push-up device, 

rigid shaft connectors, 

limit plugs, angle 

bracket

D

Upper end position freely 

adjustable, fixed lower limit 

stop

Anti push-up device, 

rigid shaft connectors 

 © 

elero

 GmbH

  

EN | 5

Assembly | Electrical connection | Adjusting the end positions 

Содержание RolMotion M

Страница 1: ...he declaration of conformity see EC Declaration of Conformity All information relating to safety in these operating instructions refers to the laws and regulations that are currently valid in Germany...

Страница 2: ...operator shall be solely responsible for any damages arising from the improper use of this product The manufacturer cannot be held liable for personal or material damages caused by misuse or procedura...

Страница 3: ...missioning of the RolMotion M with elero assembly cable for setting various functions Before installation all cables and components that are not required and all facilities that are not needed for ope...

Страница 4: ...so that the first time the plug is inserted it is connected first and in case of any damage it is disconnected last The connecting cable is fitted with mechanical strain relief when inserted in the dr...

Страница 5: ...l profiles the upper and lower end positions must first be set First program the upper end position then the lower end position The end positions and the strain relief are set via the elero assembly c...

Страница 6: ...d 6 EN elero GmbH End position adjustment Relief function Important When programming an end position to the limit stop the relief function for the blind is activated automatically The blind remains re...

Страница 7: ...s Drive stops after short time End position programmed Stiff blind Set second end position Check the smooth run ning of the blind Drive moves in the opposite direction without a new travel command and...

Страница 8: ...rformed by personnel described in the section Safety notes on electrical installation Removal for scrap The international national and regional laws and regulations prevailing at the time of scrapping...

Страница 9: ...Rated voltage V 1 230 1 230 Rated frequency Hz 50 50 Noiseless soft brake Rated current A 0 4 0 5 Rated power consumption W 92 115 Shaft diameter mm 50 50 Degree of protection IP Code 44 44 Limit swit...

Страница 10: ...We reserve the right to make technical changes elero GmbH Drive technology Maybachstr 30 73278 Schlierbach Germany info elero de www elero com...

Отзывы: