Intermediate position
Roller shutter/venetian blind
GB-10
GB
Programming additional transmitters
GB-9
Intermediate position Roller shutter/venetian blind
Programming additional transmitters
To programme additional transmitters in one receiver, please proceed
as follows:
1. Press the
UP, DOWN
and programming button
P
on a transmitter
that has already been programmed in the receiver until the LED
goes out.
2. To define the keyboard layout, press the
UP
button on the hand-
held transmitter as soon as the shutter/blind begins to move
upwards (after approx. 1 second).
The shutter/blind will come briefly to a halt.
As soon as the shutter/blind begins to move again, press the
DOWN
button on the handheld transmitter.
The shutter/blind will come to a stop.
The transmitter or this channel has been successfully programmed.
Note:
If more than one receiver is connected to the same supply
lead, all of these will be in programming mode simultane-
ously. The shutters/blinds will begin to move up and down
“at random”. The longer you take to carry out the
programming, the larger the offset will be.
Individual channels can now be assigned to the given
receiver.
To stop the brief UP and DOWN movements, press the
STOP
button on one of the pre-programmed handheld
transmitters briefly.
Channel assignment/modification can now be carried out
without you having to disconnect individual receivers.
Select the desired channel using the Select button.
If the shutter/blind moves in the wrong direction, the
transmitter must be deleted and re-programmed.
Roller shutter
Venetian blind
Pos
B
Intermediate position
Intermediate position
Pos
V
Ventilation position
Reverse position
Programming Pos
B
Prerequisite
: The transmitter has been programmed and the end
limit positions have been set. The shutter curtain/
venetian blind is in the upper end limit position.
1. Adjust the shutter curtain/venetian blind into the desired
position using the
DOWN
button.
Note:
Keep the
DOWN
button pressed until the desired
position is reached.
2. When the shutter curtain/venetian blind has reached the des-
ired position, press the
STOP
button
in addition
.
The shutter curtain/venetian blind will come to a stop. The
intermediate position has been successfully programmed.
Programming Pos
V
Prerequisite:
The transmitter has been programmed and the end
limit positions have been set. The shutter curtain/
venetian blind is in the lower end limit position.
1. Move the shutter curtain/venetian blind in the UP direction
using the handheld transmitter until the ventilation slits are
open or the reverse position has been reached.
Note:
Keep the UP button pressed until the desired position is
reached.
2. When the shutter curtain/venetian blind has reached the
desired position, press the
STOP
button in
addition
.
The shutter curtain/venetian blind will come to a stop. The
ventilation/reverse position has been successfully programmed.