background image

Installation instructions and mounting dimensions
elero folding shutter drive type KL/DMA

Mounting dimensions

As a result of different wall thicknesses, both the square drive shaft of
the inside opener and the protective sheath must be adjusted to
match the wall concerned. The following calculation formula can be
used here:

Dimension F of the inside opener = total wall thickness - 196 mm (B)

Important:

The minimum dimension for which fitting is possible is
300 mm for flush mounting. 250 – 300 mm is appropriate
for partial surface mounting.

Sample calculation

The drive is to be fitted into a wall with a total thickness of 300 mm.
Dimension "B“ (196 mm) on the folding shutter drive cannot be
changed.

Dimension " F“ is then 300 mm - 196 mm = 104 mm.

The protective sheath "E“ of the square drive shaft "D“ must be 28 mm
shorter than the drive shaft.

Installation instructions

Ensure when assembling the folding shutter drive that
the 

weight of the shutter is carried by the upper hinge

,

so that the inside opener only has to transmit the
turning moment.

Rigid stops must be attached to the shutters inside
and outside to enable the drive to function correctly.

The stops must be at the same level as the drive.

The drive and the inside opener must be properly
sealed in or bolted to the wall.

Ensure during fitting that the motor and the inside
opener are longitudinally aligned, and that the drive is
pushed all the way onto the inside opener.

elero recommends the inside openers and mountings
manufactured by Kiekert & Nieland.

The cover of the drive closes an
inspection opening, and must
be accessible at all times!

b

b

b

b

v

v

v

v

n

n

n

m

m

m

m

n

n

m

85

110

175

Y

80

l

25

120

50

190

(B) 196

8

m

n

70

m

v

b

v

v

b

Square 10 mm

l

28

40

m

n

n

m

F

28

D

E

Inside opener

Cable inlet 

The inside opener 
is not included!

Electrical voltage!
Risk of injury due to electrocution.

The connections to the 230 mains must be made by
authorised specialist personnel.

The regulations of the local energy supply company as
well as the regulations for wet and damp rooms
according to VDE 0100 must be followed when
making the connections.
• The drive must be fixed in such a way that it is not a

danger to personnel.

• The equipment must be completely disconnected

from the power supply before the drive is installed.

• If the folding shutter drive is fitted into other

equipment, the installer must ensure that EMC
guidelines continue to be observed.

• Please observe the motor's technical data.
• Please observe the appropriate instructions for the

use of controllers and window controllers.

Risk of crushing!
Risk of injury through crushing!

• Make sure that there is nobody in the area where

the folding shutter swings.

• Make sure that it is not possible to operate the

folding shutter when work such as window
cleaning is being carried out nearby.

Note!  

Make sure that moisture does not enter the
drive. 

Warning!

Warning!

GB

Отзывы: