![elero JA Comfort series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/elero/ja-comfort-series/ja-comfort-series_manual_2388004002.webp)
2 | EN
©
elero
GmbH
Adjusting the end positions and turning range
Plug drive cable assignment
PE
Yellow/green protective conductor
N
①
Neutral conductor/blue
L
1
②
Phase/black OPEN
L
2
③
Phase/brown DOWN/CLOSE
On initial commissioning, the drive is in delivery condition:
Lower end position has been reached. Upper end position
needs to be set (see
Setting upper end position
).
The end positions and turning range of the slats are set with
the
elero
assembly cable.
Connection for elero assembly cable
•
Drive is powered via “OPEN”
or
“DOWN/CLOSE” via one
of the cables a), b) or c)
a) Assembly cable 23 395.7702:
Operation with Hirschmann coupling Stas 3 (without
adapter cable and connection terminal in box) and
rotary switch in right position.
b) Assembly cable 23 243.0002 with connection terminal
c) Assembly cable 23 246.0001 with Hirschmann
coupling
•
Setting the end postions and turning range:
see “Setting the end positions and turning range”
•
If, after travel, “OPEN” and “DOWN/CLOSE” are pressed
simultaneously, setting the end positions starts and the
transmitter operation commences. After 9 seconds or
after pressing the hand-held transmitter, setting the end
positions is cancelled.
Adjusting the end positions and turning range
Turning range of slats
•
This is the range of movement in which the position
of the slats is set at low speed. The standard setting
is 270° based on the drive shaft.
•
This can optionally be changed upon setting the lower
end position, at minimum 90° (first OPEN movement plus
1 increment), maximum 360°.
Setting end positions
Generally speaking, only one end position (top or bottom)
can be reset; this leads to a deletion of the previous setting.
•
If both the top and the bottom end position are to be set,
the procedure needs to be carried out twice accordingly.
•
On initial commissioning (lower end position reached,
drive is in the setting mode for upper end position), skip
point
1
below and continue at point
2
depending on the
upper limit stop required later on.
1
. With the
elero
assembly cable connected and in middle
blind position, press the buttons
OPEN
and
DOWN/
CLOSED
simultaneously and hold them down until the
drive initiates brief upward and downward motion.
Freely configuring the upper end position without
influence of the mushroom button
2
.Press the
OPEN
buttonuntil the desired position is reached
(drive starts up, stops briefly and continues).
3
. Corrections are possible in inching mode using the OPEN
and DOWN/CLOSE buttons. If the DOWN/CLOSE button
is pressed down permanently, this position will be stored.
4
. Press the
DOWN/CLOSED
button until the drive
stops automatically.
The upper end position has been freely configured. Even if a
mushroom button is present, no reference runs will be made.
5
. Remove the assembly cable, connect the electrics, check
assignment of the travel directions.
Setting upper end position on the mushroom button
2
. Press the
OPEN
push button until the drive is stopped
by the mushroom button (drive starts up, stops briefly
and continues).
Upper end position is set and is at the position of the
mushroom button. No reference runs are performed.
3
. Remove the assembly cable, connect the electrics, check
assignment of the travel directions.
Adjust the upper end position to the cover position *)
(with cyclical reference runs)
*
)
Cover position: 3 turns of the drive shaft below the
mushroom button at maximum
2
. Press the
OPEN
push button until the drive is stopped
by the mushroom button (drive starts up, stops briefly
and continues).
3
. Press and hold down the
OPEN
button and the
DOWN/
CLOSE
button too until the desired position is reached.
Release both buttons.
Upper end position is set and is located at the position
in front of the mushroom button. Cyclical reference runs
are performed.
4
. Remove the assembly cable, connect the electrics, check
assignment of the travel directions.
Setting the lower end position and the turning range
to standard
2
. Press the
DOWN/CLOSE
button until the desired position
is reached (drive starts up, stops briefly and continues).
3
. Corrections are possible in inching mode using the OPEN
and DOWN/CLOSE buttons.
4
. Press the
OPEN
button until the drive stops automatically.
The lower end position has been set. The turning range is
set to 270° (standard).
5
. Remove the assembly cable, make an electrical
connection, check assignment of the travel directions.