elero Aquero Скачать руководство пользователя страница 2

Mounting and technical data

Technical data

 
Protection class: 

IP44 (after correct installation)

Supply voltage: 

110 V to bis 230 V, 50 to 60 Hz 

Power consumption: 

0,5 to 5 W 

Output: 

1 potential-free changeover contact 

 

5 A / 250 V

Ambient temperature: 

– 20 °C to + 50 °C

Dimensions:  

300 x 170 x 65 mm

Weight: 0,42 

kg

Maintenance

The Aquero must be freely accessible and must not be overgrown 
by vegetation.
The Aquero is maintenance-free; however, the sensor surface 
must be cleaned from time to time using a moist cloth without clea-
ning agents.

Permissible mounting position

4.  Switch off the mains voltage.
5. Connect the Aquero, observing the correct wiring colours.

PE

50 ... 60 Hz

N

L

Mains 1

10

 ... 230 V A

C Rain alarm

Mains

110 ... 230 V

50 ... 60 Hz

C

NC

NO

N

L

PE

Rain signal

Mains unit

Aquero

Multipoint connector/supply voltage

Sensor PCB

6.  Push the mains unit PCB carefully back into the wall plinth.

Make sure that the PCB is located in the guide rail.

7.  Push the mains unit PCB cover back onto the wall plinth and 

screw it tight.

8.  Switch on the mains voltage again.

After 2 minutes, the Aquero is ready for operation.

The terminal configuration in the device is as follows:
L Mains
N Mains
PE Protective earth 
C Rain 

alarm

NO Rain alarm

Connection example

aerotecaquero

PE

N
L

C

N L

Mains

2

3

1

5

3 4

6

1 2

Sensor

Central

N
L

PE

Mains

NO

C

NC

N
L

PE

Aquero

Aero

AeroTec

1

Z

M

Important safety instructions!
Observe the following instructions.

Danger of injury due to burns!

•  The sensor surface may reach a temperature of up 

to 60 °C.

•  Only touch the sensor surface with great care.

•   Check the function of the Aquero by splashing water 

onto the sensor surface..

Caution!

 

Fault 

 Cause  

Remedy

 The awning does   Aquero is dirty 

Clean Aquero

 not retract when
 it rains 

Aquero is mounted  

Mount Aquero 

    

incorrectly  

correctly 

    

   

 see ‘Permissible 

    

   

mounting position’

Troubleshooting

Horizontal wall 
 mounting position