Commissioning
(connecting a tubular motor or a venetian blind drive)
The jumpers (tubular motor/venetian blind drive connection/vene-
tian blind in pulse mode) must be installed before programming
of the transmitters.
1. After restoration of power
or
by pressing the
P
button
(at least 5 s), the Revio-868/-915 is in programming mode for
5 minutes.
2. Programme the transmitter (→ see transmitter instructions).
Programming additional transmitters
→ see transmitter instructions
Programming positions
→ see transmitter instructions
Approaching positions
→ see transmitter instructions
Deleting positions/deleting transmitters
→ see transmitter instructions
Programming the transmitter / channel
P R E R E Q U I S I T E !
The Revio-868/-915 is installed.
(→ see chapter Connection RM/JA)
The end positions must be set.
!
Technical data / Disposal /
Notes on troubleshooting
Technical data
Disposal
Dispose of the device as specified by national regulations for dis-
posal of electronic waste (e.g. suitable collection points).
Notes on troubleshooting
Fault
Cause
Remedy
Drive does not run Wrong connection
Check connection
Drive runs in the
wrong direction
Directions are incor-
rectly programmed
Delete transmitter and
programme correctly
No radio reception • Transmitter is not
programmed
• No power supply
• Programme
the transmitter
• Switch on power
supply
Bad radio
reception
Unfavourable
position of the
antenna/receiver
Change the posi-
tion of the antenna/
receiver
Nominal voltage
230 - 240 V AC / 50 to 60 Hz
Switching current
3 A
IP Code
IP 20
Permitted ambient
temperature
0 to 55 °C
Radio frequency
869,525 MHz
Transmission power
≤
500 mW
Type of installation
Flush-mounted housing, Ø 58 mm, depth 60
mm. Corresponding surface-mounted housing
Dimensions
L 50 x W 48 x H 27 mm
Maximum number
of transmitters
16 transmitters
Conformity
12 | EN
Ⓒ
elero GmbH
Ⓒ
elero GmbH
EN | 13