DoorControl

3

Functions

Motor run time monitoring

DoorControl includes programmable motor run time moni-
toring  which automatically switches the drive off in the
event of excessive motor run time. In order to programme
the motor running time the drive should be taken to the
CLOSE door position. 
Set DIP I to the ON position. Briefly press programming
button S3, LED 2 illuminates, now move the drive in self-
retention until reaching the limit switch door OPEN. LED2
goes out, the motor run time is now programmed.

.

If the programming button S3 is pressed for more than  
5 secs. (LED2 goes out) the run time monitoring is reset 
to the maximum value (0 secs.).

Locking mechanism for the door edges (OSE or 8,2 kOhm)

Should the locking mechanism for the door edges be activa-
ted during a CLOSING movement, the control switches over
to the opening direction (reversing or free movement). If the
CLOSE pre-limit switch is pressed, the drive is stopped. If the
locking mechanism for the door edges is faulty, the drive can
be operated with the built-in touch keyboard and the exter-
nal triple switch in dead man operation.

Light barrier

If the light barrier is activated during a CLOSING move-
ment, the control switches over to the opening direction
and the drive moves up to the OPEN end position. When
the automatic closing mechanism is switched on, the hold-
open time is reinitiated. Should the installation be in an
intermediate position and the light barrier is activated, the
opening direction is started.

Radio remote control Channel 1

The integrated or the internally pluggable radio receiver, as
well as the external input FS (terminal 13+14) change 
function with each activation. 
(Switching sequence UP-STOP-DOWN-UP. . .)
When the automatic closing mechanism is switched on the
radio remote control always switches on the opening 
direction. With each subsequent command, the hold-open 
time is reinitiated.
The programming must be based on the radio remote 
control in use.

Radio remote control Channel 2

Relay K3 can be additionally controlled with the second
channel.

Automatic closing mechanism

The automatic closing mechanism can be swit-
ched on and off with the rotary switch S2. 
When the automatic closing mechanism is 
switched on, the preliminary warning time swit-
ches on for approximately 5 secs. at the end of
the hold-open time. The closing procedure is then started.
The door can be opened with the “On” timer contact (terminal 10 a
and closed again with “Off” by the adjusted automatic door-edge 
security system.
If the locking mechanism for the door edges has been
activated 3 times before reaching the CLOSE limit switch
the automatic closing mechanism becomes inactive

.

Level 0

Active red traffic light and error message

Level 1

Active red traffic light, error message flashing

Level 2

Automatic closing function on,     “hold open” time 10 se

Level 3

as above 20 seconds

Level 4

as above 30 seconds

Level 5

as above 40 seconds

Level 6

as above 50 seconds

Level 7

as above 60 seconds

Level 8

as above 60 seconds (after the light barrier 
is CLOSED, the “hold open” time reduced 
by approx. 4 secs)

 

Level 9

Automatic closing function on,     “hold open” time 10 sec

LED diagnosis

LED 5 (red)

Stop button activated (terminals 9+10)

LED 4 (red)

Light barrier activated

LED 3 (red)

Illuminates when the locking 
mechanism for the door edges is 
faulty or activated

LED 2 (yellow) Programme motor run time /

radio reception

LED 1 (green) Power (operating voltage)

Flashes during OPEN and CLOSE 
movement
Flashes when the hold-open time runs out

LED 1 (green)

+ LED 3 (red)

Flashes when the running time is exceeded

mains 230V/AC

M

1~

-

+

OUT

Safety

switch

error message

Red traffic light or

Light or

green traffic light

Light or failure notification

with latching relay

Emergency

stop

Triple switch

Stop

Up

Down

pull switch

Radio remote
control,

Light barrier
closing direction
Terminals 15/17
max. 150 mA

Fraba OSE

GN

BN

WS

R 8,2 kOhm

Pre-limit switch CLOSE

or

locking mechanism for the door edges

max. 10A

Fuse on site

21 22

N

PE

PE

N

L

1

2

3

4

5

6

7

8

10

9

12

11

17

15 16

K3

L

N

PE

L

PE

N

8

7

K3

13 14

19

18

20

20

18 19

inputs/outputs

operating elements

Safety devices

Neutralization

24V DC inputs/outputs

230V AC

Terminal diagram DoorControl

230 V/max. 60 W

10 11

Timer

max. 230 V/60 W

Отзывы: