DoorControl Nr. 24 180.0101 / 24 180.0301
Rolling door control for alternating current drives
GRUPPE
GÜNTHER
GB
It is important to observe these instructions in order to guarantee safety for persons!
Do not discard these instructions!
Incorrect assembly can cause serious injury.
• Connections to the mains must be carried out by specialised personnel.
• The control must be disconnected from the mains during connestion work.
• The mains disconnection mechanism must be secured against unintentional and unauthorised
restarting and shoule always be accessible.
• Powered doors with pulsed or automatic operation must fulfil EN 12453.
• With external evaluation devices connect the 8.2 kOhm resistor in series with the switch contact.
•
Caution:
A moving door panel must not pose a risk of injury or damage.
• An 8.2 kOhm resistor can be connected in the CLOSED direction in the case of roller shutter drives.
•
Caution:
The roller shutters must not pose a risk of injury or damage.
180
130
60
230 V Mains terminals
Fuse
6,3 A tr.
Selector
switch
S 1
LED
S 2
Hold-open time
Proigramming
button
S 3
Integrated radio
receiver or slot for
radio receiver
24 V terminals
Operating appliances
Warning!
Advice:
Only tubular drives with mechanical limit switches can be connected.