6. Maintenance

6-1. Battery Replacement

1. Remove the two screws on the case cover. Then,

detach it from the top case.

2. Unsnap the battery from the connector and replace

it with a new 9 volt battery.

3. Close the case cover and secure it with the

screws.

1. Safety Information

To ensure that the meter is used safely,  follow all of
the safety and operation instructions in this manual. If
the meter is not used as described in the manual, the
safety features of the meter might be impaired.

• Do not use the meter if the meter or the test leads look

damaged, or if you suspect that the meter is not operating
properly.

• Turn off the power to the circuit under test before cutting,

unsoldering, or breaking the circuit. Small amounts of current
can be dangerous.

• Use caution when working above 60VDC or 30VAC rms.

Such voltages pose a shock hazard.

• When using the test lead, keep your fingers behind the

guards on the test lead.

• Disconnect the live test lead before disconnecting the

common test lead.

• To avoid damage to the meter, do not exceed the input limits

shown below.

• This digital multimeter is designed for indoor use only.

Refer to Section 4-2 on page 6 for complete specifications.

FUNCTION

INPUT JACK

INPUT LIMITS

VDC

V/

W

& COM

1000VDC or 750Vrms AC

VAC

V/

W

& COM

1000VDC or 750Vrms AC

W

/

V/

W

& COM

220Vrms @ 15 sec.

m

A, mA DC

10A DC

mA & COM

10A & COM

200mA DC

10A DC

-14-

-3-

WARNING

Before attempting battery & fuse removal or
replacement, disconnect the test leads from any
energized circuits to avoid hazard.

+

Содержание M-1000B

Страница 1: ...OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER M 1000B Copyright 2003 ElencoTM Electronics Inc...

Страница 2: ...ion 8 9 5 3 How to Make Measurements 10 13 6 Maintenance 14 6 1 Battery Replacement 14 6 2 Fuse Replacement 15 WARNING PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY Misuse and or abuse of this instruc...

Страница 3: ...ircuit Small amounts of current can be dangerous Use caution when working above 60VDC or 30VAC rms Such voltages pose a shock hazard When using the test lead keep your fingers behind the guards on the...

Страница 4: ...hat the terminal s so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds in this case 500 volts This symbol adjacent to one or more terminals ide...

Страница 5: ...y 3 1 2 LCD 1999 count display Polarity Automatic is displayed Overrange Indication 1 on LCD is displayed Operation Temperature 32O F to 122O F Power 9V Alkaline or Carbon Zinc battery NEDA 1604 Batte...

Страница 6: ...0 8 of rdg 2dgt OVERLOAD PROTECTION 220Vrms AC for 200mV range and 1000VDC or 750Vrms AC for other ranges AC Voltage 200V 100mV 1 2 of rdg 10dgt 750V 1V 1 2 of rdg 10dgt OVERLOAD PROTECTION 1000VDC f...

Страница 7: ...of rdg 2dgt OVERLOAD PROTECTION 15 seconds maximum 220Vrms on all ranges MAXIMUM OPEN CIRCUIT VOLTAGE 2 8V TR hFE NPN 10mA DC 3 0V DC PNP 10mA DC 3 0V DC DIODE TEST Measures forward resistance of a s...

Страница 8: ...rors 3 Avoid using the unit in places with rapid temperature variations 4 In order to prevent damage or injury to the unit never fail to keep the maximum tolerable voltage and current especially for t...

Страница 9: ...1 2 6 3 5 4 9...

Страница 10: ...ement 1 Plug the red test lead into the V W mA jack and the black test lead into the COM jack 2 Set the RANGE switch to the desired DCV position If the voltage to be measured is not known beforehand s...

Страница 11: ...ear on the digital display DC Current Measurement 1 Plug the red test lead into the V W mA jack and the black test lead into the COM jack for measurements between 200mA and 10A connect the red test le...

Страница 12: ...easuring 4 Connect the test leads to the circuit to be measured 5 Read the resistance value on the digital display Diode Measurement 1 Plug the red test lead into the V W mA jack and the black test le...

Страница 13: ...ine whether the transistor is an NPN or PNP type and locate the Emitter Base and Collector leads Insert the leads into the proper holes of the hFE socket on the front panel 3 The meter will display th...

Страница 14: ...it from the top case 2 Unsnap the battery from the connector and replace it with a new 9 volt battery 3 Close the case cover and secure it with the screws 14 WARNING Before attempting battery fuse re...

Страница 15: ...rom the back of the case 3 Remove the fuse from the holder and replace it with a new fuse of the specified value Fuse Numbers 200mA 250V Bussman Fuse GMA 2 10 200mA 250V Little Fuse 235 200 200mA 250V...

Страница 16: ...Elenco TM Electronics Inc 150 W Carpenter Avenue Wheeling IL 60090 847 541 3800 http www elenco com e mail elenco elenco com...

Отзывы: