33

2.  Under swing up and down mode, when the status is switched from off to  , if 

press this button again 2s later,   status will switch to off status directly; if press 

this button again within 2s, the change of swing status will also depend on the 

circulation sequence stated above.

Switching between Fahrenheit and centigrade

Under status of unit off, press MODE and - buttons simultaneously to switch ºC and 

ºF.

Function of defrosting

It indicates: after starting this function by remote controller and the unit has been 

under defrost status, If turn off the unit by remote controller, the unit will not stop de

-

frosting until it is finished; if change setting mode by remote controller, the function 

,which is set last time, won’t be carried out until defrosting finished.

Operation of this function on or off: If remote controller is under off status, press mode 

button and blow button simultaneously in order to enter or cancel this new function. 

If the unit is under defrost mode, dual eight position on remote controller will display 

H1 in this case, press +/- button, H1 will disappear and setting temp. be displayed.

After remote controller is powered on, the new defrost function will be defaulted to 

be closed.

changing batteries and notices

The  wireless  remote  control  adopts  two  new  AAA  1.5  V 

dry batteries.

1.  Slide  the  cell  cover  downward  to  take  out  the  worn 

cells, then change 2 new ones (note to the correct po

-

larity).

2.  Cover the cell cover.

NOTE:

•  When changing the batteries, do not use the old or dif

-

ferent batteries, otherwise, it can cause the malfunc

-

tion of the wireless remote control.

•  If the wireless remote control will not be used for a long 

time, please take them out, and don’t let the leakage 

liquid damage the wireless remote control.

•  The operation should be in its receiving range.

•  It should be placed at where is 1m away from the TV set or stereo sound sets.

•  If the wireless remote control can not operate normally, please take them out, 

after 30s later and reinsert, if they cannot normally run, please change them.

Содержание SPT-7080

Страница 1: ...SPT 7080...

Страница 2: ...3 4 4 5 6 8 10 10 11 11 12 14 15 15 15 15 16 16 16 17 18 19 20 22 22 23...

Страница 3: ......

Страница 4: ...ELENBERG 1...

Страница 5: ...0 1 2 3 4 5 6 7 8 9...

Страница 6: ...ON OFF MODE 25 C SLEEP FAN CLOCK 5 10 CLOCK BLOW TURBO TURBO...

Страница 7: ...16 30 61 86 F LIGHT TIMER ON ON 5 1 Timer On Timer On TIMER OFF...

Страница 8: ...1 ON OFF 2 MODE 3 4 FAN 5 1 SLEEP 2 TIMER ON TIMER OFF 3 LIGHT 4 TURBO 1 ON OFF 10 BLOW 2 ON OFF 1 2...

Страница 9: ...F MODE C F mode blow H1 1 5 AAA 1 2 1 30...

Страница 10: ...10 AUTO STOP AUTO STOP AUTO TEST STOP 1 2 45 C 3...

Страница 11: ...11 1 b 2 45 C 3 1 2 3 4 1 2 3...

Страница 12: ...12 3...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15 1 2 3 1 2 3 4 5 230 6 1 7 8 1 2 3 4 5 6 7 5 10 8 9...

Страница 16: ...16 1 2 3 4 1 5 1 I 2 3 4 A B C D 1 2 3 4 5...

Страница 17: ...17...

Страница 18: ...18 1 2 3 60 1 2 1 2 3 1 2 3 4 5 6 7 1 2...

Страница 19: ...19 1 1 2 1 2 1 2 3 2 3 3 4 1 2 6 15 20 9 2 31 35 12 50 55 16 60 65 19 70 75 1 2 3 4 5 1 2 3 4...

Страница 20: ...20 0 5 15 1 0 x 105 76 cmHg 6 7 8 5 1 b 2...

Страница 21: ...21 3 1...

Страница 22: ...22 220 240 50 1 2 3 4 1 ON OFF 2 MODE...

Страница 23: ...23 220 240 50 2050 7000 820 1000 3 5 400 3 0 8 1060 960 860 760 8 7 1 5 PCB 3 15 A 710 X 180 X 250 7 11 730 B130 130 241C 10 48 7 950 20 1200 3 324 T1 I IP24...

Страница 24: ...24 2 5 720 X 430 X 260 25 29 R22 430 5 20 6 9 52 5 10 3 18 148...

Страница 25: ...Split air conditioner SPT 7080 Instruction manual...

Страница 26: ...38 Important notices 39 Basic requirements for installation position 39 Indoor unit installation position selection 39 Indoor unit installation position selection 39 Safety requirements for electric a...

Страница 27: ...27 Operating manual...

Страница 28: ...off the unit frequently otherwise disadvantage ef fect may be caused to the unit When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnor...

Страница 29: ...med on the heat exchanger when indoor heat exchanger temperature de creased below 0 the indoor unit microcomputer will stop compressor running and protect the unit 1 Power cable 2 Front panel 3 Filter...

Страница 30: ...an be circularly selected After powered on Auto fan speed is default Under Dehumidify mode Low fan speed only can be set up CLOCK button Press this button the clock can be set up signal blink and disp...

Страница 31: ...and down button Press this button to set up swing angle which circularly changes as below This is an universal use remote controller If remote controller sends the following three kinds of status tha...

Страница 32: ...nit by pressing ON OFF button indoor fan will continue running for about 10 min at low speed In this period press blow button to stop indoor fan directly 2 Having set blow function off After turning o...

Страница 33: ...or cancel this new function If the unit is under defrost mode dual eight position on remote controller will display H1 in this case press button H1 will disappear and setting temp be displayed After...

Страница 34: ...ef fect At stopping When the unit is running adjusts the code switch to STOP position the unit will stop work Caution Turn power off and pull out the power plug before cleaning air conditioner Or it m...

Страница 35: ...nt should below 45 C When the filters are very dirty such as oil stain and dry it in the shade NOTE Never use water above 45 C to wash or it can cause deformation or discoloration Never partch it by f...

Страница 36: ...unning or the air condi tioner is stopped sometimes you may hear hua hua or di di noise This is the flowing sound of refrigerant other than fault Sometimes a thin fog will flow out of the outlet when...

Страница 37: ...flowed out When the unit is running in HEAT mode the water adhered on heat exchanger dripped off Noise from indoor unit emitted The sound of fan or compressor relay is switching on or off When the de...

Страница 38: ...38 Installation manual...

Страница 39: ...and the full weight and vibration of the unit And will not increase the noise 5 Be sure to leave enough space to allow access for routine maintenance The height of the installed location should be 230...

Страница 40: ...opose It cannot be cut off and be fix it by screw otherwise it would cause electric shock 3 The earth resistance should accord to the National Criterion 4 The user power must offer the reliable earthi...

Страница 41: ...41 Installation dimension diagram...

Страница 42: ...electric wires 1 Open the front panel upwardly 2 Screw off the fixing screw of cover plate and screw off cover plate 3 Put the power connection cable through the back of indoor unit wire hole and tak...

Страница 43: ...ape and put them through the piping hole As show in Fig 3 3 Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough As show in Fig 4 Install the c...

Страница 44: ...the vacuum pump to evacuate At the beginning slightly loosen joint nut of low pres sure valve to check if there is air coming inside If noise of vacuum pump has been changed the reading of multimeter...

Страница 45: ...ed with water while active carbon photocatalyst low tempera ture conversion LTC catalyst formaldehyde eliminator catechin or mite killing filter can but can t with brush or hard things Dry it in the s...

Страница 46: ...t may cause electrical leakage Is the power cord specified It may cause electric malfunction or dam age the part Is the inlet and outlet been cov ered It may cause insufficient cooling heating capacit...

Страница 47: ...utput of Swing Motor W 1 5 Fuse A PCB 3 15 A Dimension W H D mm 710 X 180 X 250 Net Weight Gross Weight kg 7 11 Outdoor unit Compressor Type Rotory Compressor Power Input W 730 Overload Protector B130...

Страница 48: ...erant Charge kg R22 0 43 Connection pipe Length m 5 Gas additional charge g m 20 Outer Diameter Liquid Pipe mm 6 Gas Pipe mm 9 52 Max Distance Height m 5 Length m 10 DESIGN AND SPECIFICATIONS ARE SUBJ...

Отзывы: