TH232-AF-230
400-232-003-B 2010-05-26 3/4
NOTE: Early Start can be used in Automatic mode only. When this
function is set to On, the thermostat calculates the optimal time to
start heating in order to obtain the desired temperature by the set
time. The thermostat re-assesses the start time daily based on the
previous day’s results.
n
Press the
Hour
button to set the hour.
o
Set the
Min
button to set the minutes.
p
Set the
Day
button to set the day.
q
Press
Mode/Return
to exit and save the changes.
Daylight Savings (DLS) Time
When the
DLS
function is set to
US
, the thermostat switches to Day-
light Savings Time on the second Sunday of March and to normal
time on the first Sunday of November.
When the
DLS
function is set to
Eu
, the thermostat switches to Day-
light Savings Time on the last Sunday of March and to normal time
on the last Sunday of October.
NOTE: The DLS function is OFF (default setting) when the clock
loses its setting.
n
Press the
Day
button (3 seconds) until
DLS
appears
on the screen.
o
Press the
to toggle between
US
,
Eu
and
OFF
.
p
Press the
Day
button briefly. The year setting is dis-
played.
q
Press the
to set the current year.
r
Press the
Day
button briefly. The month setting is dis-
played.
s
Press the
to set the current month.
t
Press the
Day
button briefly. The date setting is dis-
played.
u
Press the
to set the current date.
v
Press
Mode/Return
to exit and save the changes.
6.1
Setpoint Temperature
The thermostat normally displays the actual (measured) temperature.
To view the setpoint, press one of the
buttons once. The setpoint
will appear for the next 5 seconds.
To change the setpoint, press one of the
buttons until the desired
temperature is displayed. To scroll faster, press and hold the button.
Backlight
The screen is lit for 12 seconds when any button is pressed.
6.2
Preset Temperatures
The thermostat has 2 preset temperatures:
Comfort temperature
Economy temperature
To use a preset temperature, press the corresponding button. The
corresponding icon will be displayed.
The following table shows the intended use and the default value of
each of the preset temperatures.
To store a preset temperature:
n
Set the desired temperature using the
buttons.
o
Press and hold the corresponding temperature preset button
until the corresponding icon is displayed.
The thermostat has 2 modes of operation: automatic mode and man-
ual mode.
7.1
Automatic Mode
Use automatic mode if you want the thermostat to fol-
low the programmed schedule. The schedule has 4
time periods and uses the 2 preset temperatures. The
thermostat switches to Comfort temperature in periods
1 and 3 and to Economy temperature in periods 2 and
4. The following table shows the intended use of each
time period.
To use the automatic mode, press the
Mode
button to display on
the screen. The current period number will also appear.
Preprogrammed schedule
The thermostat has been programmed with the following schedule.
Temporary bypass
You can override the temperature of the current period by pressing
the
,
or buttons. The new setpoint will be used until the begin-
ning of the next period. The clock icon flashes during the bypass.
To cancel the bypass, press the
Mode
button.
r
Clock and Day Setting
5.
s
Temperature Adjustment
6.
Icon
Intended use
A/AF modes
F mode
Comfort
(when at home)
21 °C (70 °F)
28 °C (82 °F)
Economy (when asleep
or away from home)
16.5 °C (62 °F)
20 °C (68 °F)
t
t
Modes of Operation
7.
Period
Temperature setting
Typical use
Comfort
Wake-up
Economy
At work
Comfort
At home
Economy
Sleep
Period
Temperature
setting
Period start time
MO
TU
WE
TH
FR
SA
SU
Comfort
6:00
am
6:00
am
6:00
am
6:00
am
6:00
am
6:00
am
6:00
am
E
conomy
8:30
am
8:30
am
8:30
am
8:30
am
8:30
am
--:--
--:--
Comfort
4:00
pm
4:00
pm
4:00
pm
4:00
pm
4:00
pm
--:--
--:--
Economy
11:00
pm
11:00
pm
11:00
pm
11:00
pm
11:00
pm
11:00
pm
11:00
pm