  IMPORTANT SAFETY INFORMATION 

 

 

 

• 

WARNING: 

Always shut off gas supply at the shut-off valve and disconnect the quick 

disconnect 

socket from the main gas supply when the fire table is not in using. 

• 

WARNING: 

Installation 

and service must be performed by a qualified installer, service agency or 

gas supplier. 

• 

WARNING: 

Failure to follow with the safety warnings and precautions in this manual 

may result in serious bodily injury or death, a fire or an explosion causing damage to 
property. 

• 

IMPORTANT NOTICE: 

Read and understand all warnings and precautions prior to 

assembly and use your gas fire table. Improper installation, adjustment, alteration, 
service or maintenance can cause injury or property damage. 

• 

NOTE: 

The use and installation of this product must conform to local codes. In the absence of   

local code s, use the National Fuel Gas Code, ANSI Z21.97. Reference to Natural Gas and Propane 
Installation code CSAB14 9.1 or Propane Storage and Handling code B149.2. 

• 

NOTE: 

When an 

appliance is for connection to a fixed piping system, the installation must conform 

with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI 
Z223.1/NFPA 54, or International Fuel Gas Code. 

• 

Minimum clearance from unit to comb

ustible materials 72” (182.9cm) from the top; 48” (121.9 cm) 

from all sides and back. Do not locate this fire table under any overhead enclosure. 

• 

Always use this outdoor fire table on a hard, level non-combustible surface such a concrete, rock or 
stone. An asphalt or blacktop surface may not be acceptable for this purpose. Surfaces such as dirt 
and grass may prevent the unit from having proper ventilation. 

• 

This gas 

fire table and its individual shut off valve must be disconnected from the gas supply 

piping system during any pressure testing of that system at test pressures in excess of 1/2 of psi 
(3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its 
individual manual shut off valve during any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psi (3.5 kPa). 

• 

Keep these instructions for future reference. If you are assembling this unit for someone else, 
give this manual to him or her to read and keep for future reference. 

• 

This gas 

fire table must be used ONLY out doors in a well- ventilated space and shall NOT be 

used inside a building, garage, or any other area. 

• 

DO NOT use this outdoor gas fire table for indoor heating. Toxic carbon monoxide fumes 
can accumulate and cause asphyxiation. 

• 

NEVER leave this gas fire pit unattended when in use. 

• 

Children should be alerted to the hazards of high surface temperatures and kept at a safe 
distance while fire table is in use. 

IF YOU SMELL GAS:

 

Shut off gas supply to the fire table. 

Extinguish any open flame. 

Do not try lighting any appliance. 

Do not touch any electrical switch, do not use any phone in your building. 

Immediately call your gas supplier from a neighbor’s phone. 

If you cannot reach your gas supplier, call the fire department. 

 

WARNING   

FIRE TABLE IS FOR OUTDOOR USE ONLY 

Содержание OFM103-NG

Страница 1: ...ury or property damage Save these instructions for future reference If you are assembling this unit for someone else give this manual to him or her to read and save for future reference DANGER If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Do not store or use g...

Страница 2: ... Warnings 5 Parts List 7 Pre use Instructions 8 Lighting Instructions 12 Care and Cleaning 13 Gas Component Connection Checks 14 Troubleshooting 16 Warranty 18 CARBON MONOXIDE HAZARD Never use this appliance in an enclosed space such as camper tent car or home DANGER ...

Страница 3: ...vel non combustible surface such a concrete rock or stone An asphalt or blacktop surface may not be acceptable for this purpose Surfaces such as dirt and grass may prevent the unit from having proper ventilation This gas fire table and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 of...

Страница 4: ...e or loose clothing when operating this outdoor fire table DO NOT use in windy conditions Keep all electrical cords away from a hot outdoor fire table Certain areas of this outdoor fire table when in use will become too hot to touch Do not touch hot surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot holders or heat resistant gloves or mittens to avoid bur...

Страница 5: ...l gas is extremelyflammable and hazardousifhandled improperly Chemicals known to the state of California to cause cancer birth defects or other reproductive harm are created by the combustion of natural gas Your natural gas fire pit is designed to operate on natural gas only at a pressure of seven inches water column 7 W C Check with your gas utility for local gas pressure because in some areas natu...

Страница 6: ... The outdoor fire table must be isolated from the gas supply piping system by closing the Individual manual shut off valve during any pressure testing of the gas supply piping system at least equal to or less than 1 2 psi 3 5 kPa NATURAL GAS DANGERS AND WARNINGS Continued During any high pressure testing of the gas supply piping system at test pressures in excess of psi 3 5 kPa the appliance and it...

Страница 7: ...7 18 PARTS LIST Fire Table 1 Natural Gas Hose 1 and QuickDisconnect Lava Rock 1 ...

Страница 8: ...luded Place lava rock by hand DO NOT dump bag out in to the tray to avoid clogging the burner with dust Position the lava rock 10kgs to a level about 1 above the t opof the burner Make sure that you do not block the igniter box with lava rock to ensure proper ignition 2 1 ...

Страница 9: ...t connection must be made outdoors House Natural Gas Piping Connecting theSocket Coat the gas supply pipe nipple with gas resistant pipe compound or approved Teflon PTFE tape Screw socket onto gas supply pipe house gas source asshown to the right and wrench tighten The quick disconnect socket should never be connected to the fire table Direction of gas flow is indicated on the socket Wall 3 4 ...

Страница 10: ...ect socket and insert the unattached end of the gas hose into the socket Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked position After making all connections perform a leak test as described on page 11 of this manual Wall 5 ...

Страница 11: ... soap with 3 parts water in a spray bottle Make sure control knob is OFF Then turn natural gas on at its source Spray leak solution on valve connections paying particular attention to the areas indicated by arrows If any bubbles appear turn natural gas off reconnect and re test If you continue to see bubbles after several attempts disconnect natural gas source and contact Elementi at 1 909 985 555...

Страница 12: ... Long Match or Lighter 1 Prior to lighting use a shovel to move the lava rocks for access to the burner 2 Wearing heat resistant gloves position the burning long match or burning butane lighter near the side of the burner Do NOT lean over the fire table while lighting 3 Turn control knob counter clockwise to LIGHT 4 Remove long match long butane lighter 5 After lighting use a shovel and heatresist...

Страница 13: ...nless Steel Cleaner apply using a soft cloth in the same direction of the polish lines 4 Note Even the finest cleaning powders can scratch or burnish a mill rolled finish On polished finishes rubbing or wiping should be done in the direction of polishlines Use of proprietary names is intendedly indicating type of cleaner and does not constitute an endorsement Omission of any proprietary cleanser d...

Страница 14: ...ke sure the electrode wire is correctly connected Both elect rode wires must be fully inserted in to the igniter box 2 Make sure that the pilot housing is unobstructed Clear any debris on top of the pilot housing and make sure there is no debris between the igniter pin thermocouple and the burner tube CORRECT INCORRECT ...

Страница 15: ...pointed straight to the thermocouple The thermocouple should be positioned 5mm away from the burner tube Thermocouple Wire Valve Thermocouple Wire Igniter Box Valve 4 Make sure that the thermocouple wire is correctly positioned The thermocouple wire should be in line with the valve 5 Make sure thermocouple wire is not resting against any metal surfaces along its run This would affect its function ...

Страница 16: ...ll not light with match Possible Cause 1 No Gas Flow Check if Natural Gas supply is stopped If it is not stopped refer to Problem Sudden drop in gas flow on the following page Possible Cause 2 Quick Connect not fully engaged Disconnect the quick connect at the gas supply and reconnect to ensure a proper connection is made Possible Cause 3 Obstruction of gas flow Check for bent or kinked hose Possibl...

Страница 17: ...econnect the quick disconnect socket turn on the main gas supply and perform a leak check at the natural gas connection Problem Irregular flame pattern flame does not run the full length of the burner Possible Cause 1 Burner ports are clogged or blocked Clean burner ports Do this by inserting a paperclip in to each of the burner ports to ensure they are not clogged WARNING Make sure burner is not on...

Страница 18: ...or modifications made by anyone other than Elementi or its authorized agents will void this warranty and any damage caused by such is also not covered under this warranty Minor chipping weather fading water staining and non structural hairline cracks are typical of the material of this product and are not covered under this warranty Some color and texture variation is typical of the material and f...