background image

7 / 20

HOSE & REGULATOR ASSEMBLY AND REPLACEMENT

1. This fireplace comes equipped with a standard LP gas hose and regulator including the appliance 
side connection for a CGA No 791 Cylinder Connection Device. The LP gas hose and regulator 
supplied with this fire table must be used. Only a hose and regulator specified by manufacturer can 
be used for replacement.
a. The CGA No 791 connection incorporates a magnetic flow limiting device that acts to limit the flow 
of gas if a leak is detected between the regulator and the burner valve.
b. If the burner valve is open prior to the LP gas cylinder service valve being opened, the connection 
will interpret this free flow of gas to be a leak.
c. The connection safety feature will reduce gas flow from the regulator to the appliance to a minimal
 level.
d. Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to 
ensure that the connection flow limiting device is not triggered mistakenly.
e. If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder service 
valve and the burner valve, wait 10 seconds to allow the device to reset, open the cylinder service 
valve, then open the burner valve and light the fireplace as per lighting instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts 
any hot surface
3. Regular maintenance of the hose and regulator:
a. Inspect the hose before each use of the fire table. If the hose shows signs of cracks, abrasions, 
cuts or damage of any kind, do not operate the appliance. Fix or replace the hose as required before 
using the appliance. For assistance with repair or replacement of the hose, call Elementi at 
800-678-7294 . Use only replacement parts from the manufacturer.
b. Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when replacing the 
cylinder or at least once per year. If there is any indication of damage, have the seal replaced by a 
certified gas dealer before operating the appliance.
4. Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve. 
Hand tighten only.
5. Be careful to not cross the threads on the connection when tightening the CGA No 791 connection 
on to the LP gas cylinder service valve.
6. “Leak Test” should always be performed after attaching the connection to the LP gas cylinder
service valve. (See “Checking for Leaks” section of this manual on page 12)
7. For the connection of the hose and regulator to the LP tank, refer to the “Connection” section of
the LP gas cylinder section above.

Содержание OFG105

Страница 1: ...ed by a qualified installer service agency or gas supplier Improper Installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment Save these instructions for future reference If you are assembling this unit for someone else give this manual to him or...

Страница 2: ...ate of California to cause cancer birth defects and reproductive harm Wash your hands after handing this product Handing the brass material on this product exposes you to lead a chemical known to the State of California to cause cancer birth defects or reproductive harm Important Safety Information 3 Propane LP Dangers and Warnings 5 Hose Regulator Assembly and Replacement 7 Parts List 8 Assembly ...

Страница 3: ...f that system at test pressures in excess of 1 2 of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Keep these instructions for future reference If you are assembling this unit for someone else give this man...

Страница 4: ...control system and any gas control which has been under water DO NOT wear flammable or loose clothing when operating this outdoor fire table DO NOT use in windy conditions Keep all electrical cords away from a hot outdoor fire table Certain areas of this outdoor fire table when in use will become too hot to touch Do not touch hot surfaces until the unit has cooled unless you are wearing protective...

Страница 5: ...g any LP gas product Propane Characteristics Flammable explosive under pressure heavier than air and settles in pools in low areas In its natural state propane has no odor For your safety an odorant has been added Contact with propane could burn your skin Propane is extremely flammable and hazardous if handled improperly LP GAS WARNINGS Cylinders must be stored outdoors in a well ventilated area o...

Страница 6: ... 80 full c If the information in a and b is not followed exactly a fire causing death or serious injury may occur LP gas cylinders should be filled only by a certified LP gas dealer The pressure regulator is set for 11 inches of water column pressure The maximum inlet gas pressure for this outdoor fire table is 14 inches of water column pressure Never attempt to attach this appliance to the self c...

Страница 7: ... the burner valve and light the fireplace as per lighting instructions 2 Be sure to protect the hose from any hot surfaces Serious danger may result if the hose contacts any hot surface 3 Regular maintenance of the hose and regulator a Inspect the hose before each use of the fire table If the hose shows signs of cracks abrasions cuts or damage of any kind do not operate the appliance Fix or replac...

Страница 8: ...8 20 PARTS LIST 1 Fire Table 1 2 LP Regulator and Hose 1 3 Lava Rock 1 4 Battery 1 4 3 1 _ 2 ...

Страница 9: ...9 20 ASSEMBLY INSTRUCTIONS 1 Install the AAA battery as shown in the diagram below Battery not included _ ...

Страница 10: ...nly Disconnecting the LP Gas Tank Make sure the valve on the LP gas tank is OFF Disconnect by turning the knob counter clockwise until it is detached from the valve A statement indicating that other cylinders may be acceptable for use with the appliance provided they are compatible with the appliance retention means and accompanied by illustration s depicting the cylinder mounted to the appliance ...

Страница 11: ... top of the burner Make sure that you do not block the igniter box with lava rock to ensure proper ignition 11 20 FIREPIT FIREPIT Adjustable feet has pre installed on the bottom of fire pit already Please adjust the hight of feet to make sure all fire pit was on level always or increase the height of fire table as your preference Please make sure the height was safty before you complete ...

Страница 12: ...fter several attempts disconnect LP gas source and contact Elementi at 800 678 7294 for assistance If no bubbles appear after one minute turn tank OFF wipe away solution and proceed Check for leaks at these locations WARNING Before using this outdoor fire table make sure you have read understand and are following all information provided in the Important Safety Information section of this manual F...

Страница 13: ... the fire table while lighting 3 Turn control knob counterclockwise to LIGHT 4 Remove long match long butane lighter 5 After lighting use a shovel and heat resistant gloves to carefully move the lava rocks back into their proper position and replace the glass panel 6 After lighting rotate the burner control knob counter clockwise to Low setting Observe flame make sure all burner ports are lit Flam...

Страница 14: ...inless Steel Cleaner and Polish Arcal 20 Lac O Nu LuminWash O Cedar Cream Polish or Stainless Shine this will provide a barrier file to minimize fingerprints 3 For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish Allchem Concentrated Cleaner Samae Twinkle Cameo Copper Cleaner Liquid Nu Steel Copper s or Revere Stainless Steel Cleaner apply using a soft cloth in the same ...

Страница 15: ...correctly connected Both electrode wires must be fully inserted into the igniter box 2 Make sure that the pilot housing is unobstructed Clear any debris on top of the pilot housing and make sure there is no debris between the igniter pin thermocouple and the burner tube CORRECT INCORRECT Igniter Box Thermocouple Wire Igniter Box Valve the inner side ...

Страница 16: ...pin should be pointed straight to the thermocouple The thermocouple should be positioned 5mm away from the burner tube 16 20 Thermocouple Wire Valve Wire should be in line with valve Valve Igniter Box 4 Make sure that the thermocouple wire is correctly positioned The thermocouple wire should be in line with the valve Thermocouple Wire 5mm 0 196 ...

Страница 17: ...ble Cause 1 No Gas Flow Check if the LP gas tank is empty If empty replace and refill If the propane tank is not empty refer to Problem Sudden drop in gas flow on the following page Possible Cause 2 Coupling nut and regulator not fully connected Turn the coupling nut about one half to three fourths a turn until you feel a solid stop Do not use tools tighten by hand only Possible Cause 3 Obstructio...

Страница 18: ...use Burner ports are clogged or blocked Clean burner ports Do this by inserting a paperclip into each of the burner ports to ensure they are not clogged WARNING Make sure burner is not on and the gas supply has been properly disconnected Allow 15 minutes for unit to cool before touching it Problem Flame blow out Possible Cause 1 High or gusting winds Increase flame to HIGH setting Possible Cause 2...

Страница 19: ... lines must be installed by a licensed gas fitter Damage caused by shipping staining and abuse are not covered under this warranty Dings dents and scratches fading and natural weathering are not covered under this warranty Decorative rock is not covered under this warranty Improper installations repair or modifications made by anyone other than Elementi will void this warranty and any damage cause...

Страница 20: ...Ocean Rock USA LLC 1300 W 9th St Upland CA 91786 www elementifire com info elementifire com Tel 800 678 7294 ELEMENTI THE ART OF FIRE ...