OPERATING the FIREPLACE

Element4 Gas Fireplaces

                                                                                                                                                    

 

European

Home

.com

Automatic Turndown.

1. In Manual/Temperature/Timer modes, the valve will turn to pilot flame if there is no change in flame height for a six hour 
period. In Temperature or Timer mode, if the ambient room temperature changes, the flame height will adjust automatically to 
maintain set temperature and the fire will continue to function normally. The valve will turn to pilot flame if the set temperature 
and the ambient room temperature remain the same over a six hour period.

2. The valve turns to pilot flame if the temperature in the receiver is higher than 140°F/60°C. The main burner comes back on only 
when the temperature is below 140°F/60°C.

Automatic Shut Off.

1. With low battery power in the receiver, the system shuts off the fire completely. This does not happen if the power supply is 
interrupted.

2. The system shuts off the fire completely if there is no change in flame height for 5 days.

3. The system shuts off the fire if the main burner does not completely ignite approximately 20 seconds after ignition or after 
pushing the 

Ç

 button.

Temp - Nighttime setback Temperature mode.

The appliance must be in standby mode, pilot ignited. The room temperature is measured and compared to the nighttime 
setback temperature. The flame height is then automatically adjusted to achieve the nighttime setback temperature.

Timer mode.

The appliance must be in standby mode, pilot ignited. The Timer setting allows you to set 2 burner 

Temp 

times and 2 burner 

Temp 

times every 24 hrs.

For 

Temp

 to operate as a thermostat, TEMP must be set at 4°C or higher.

If the  

Temp

 setting is decreased to - -, the motor will turn the valve to the standby position in the moon times and await the 

next burner 

Temp

 cycle.

Setting the Temperature.

Select either the 

Temp

 MODE or the 

Temp

  MODE by briefly pressing the 

SET

 button.

Hold the 

SET

 button until the TEMP display flashes.

Set the desired temperature with

È

or

Ç

.

Press 

OFF

 to complete the program.

Setting the Timer.

Select Timer mode by briefly pressing the 

SET

 button.

Press and hold the 

SET

 button until the P1

 is displayed, and the time flashes. Set the hour by pressing

Ç

and set the minutes by 

pressing

È

.

Briefly press 

SET

 button for the next burner cycle time.

Once all 4 times are set, press 

OFF

 to complete the  programming.

MANUAL

 KNOB IN 

ON

 POSITION

MAIN VALVE 

KNOB 

IN 

OFF

 POSITION

E

LEMENT

 4

4 B

UTTON

 R

EMOTE

(Gas Valve)