Element EACF05000W Скачать руководство пользователя страница 10

the upper side of the hood into the hole on the cabinet shell, and finally fix the four screws of the hood.

 

2.

 

Changing the door gasket

 

       

     

       

 

Tear  off  the  door  gasket corner  from  one side,  remove  the  door  gasket  in  the  desired  direction,  and 
replace it with a new one, paying attention that the side with hole should be placed at the lower side; 
finally, squeeze the gasket with hand to ensure that all are installed in place.

 

V.

 

Common faults analysis 

 

1.

 

Troubleshooting

 

⚫ 

If the compressor does not work but the light is working normally, please check whether the power cord 

(or the compressor connecting wire) is well connected.

 

 If the refrigerator circuit is normal, please check the resistance of the thermostat.

 

2.

 

Running check 

 

⚫ 

Close the door after it runs for 30 minutes, if the freezer compartment temperature drops significantly, it 

indicates the refrigerator system is working properly. After running a period of time, the freezer thermostat 
will automatically set temperature within the startup range.

 

⚫ 

  The  marks  on  the  temperature  control  knob  indicate  the  temperature  level,  rather  than  the  exact 

temperature. “Off” stands for “ Power Off” and “5’ stands for the minimum temperature

 

Содержание EACF05000W

Страница 1: ...CHEST FREEZER INSTRUCTION MANUAL Model No EACF05000W EACF07000W EACF09000W EACF14100W...

Страница 2: ...ncy V Hz 115V 60Hz Rated current A 1 49 Power consumption kw h 24h 0 786 Total power input of defrost W 80 Fridge lamp W Cooling capacity Kg 24h Refrigerant R600a 100g Deodorizing method Energy consum...

Страница 3: ...1001 1 1 3 5 A4 1 10 indicate light 890045110 G1001 4 1 3 LG 1 11 indicate light 890045110 G1001 4 1 3 LG 1 12 Thermostat cover 890226945 GC1311 4 1 2 MA1 1 13 Thermostat 890141511 G1009 4 1 DU 1 14 T...

Страница 4: ...I Cooling system 1 Schematic diagram...

Страница 5: ...arm Cold normal Chart b 14 69PSI F Forcefully disconnected 5 8 22 3 2 11 2 WPF30 Atmospheric pressure Unit ON OFF ON OFF ON OFF Warm Cold normal Chart c 14 69PSI F Forcefully disconnected 14 8 25 6 4...

Страница 6: ...temperature reaches the turn off temperature Toff the compressor will get switched off III Product operation instructions 1 Temperature setting modes OFF Forced Shutdown Point 1 5 Frozen Interval from...

Страница 7: ...RE THIS TIME DELAY THE REFRIGERATOR FREEZER WILL NOT START NOTE WE DO NOT RECOMMEND THE INSTALLATION OF THE FREEZER WHERE THE TEMPERATURE WILL DROP BELOW 50 F 13 C OR RISE ABOVE 110 F 43 C THE COMPRES...

Страница 8: ...Compressor will not be started again until five minutes after it is shut down IV Repair guide Steps to change the door Open the door remove the upper and lower hinge covers on the left and right side...

Страница 9: ...ox using the thumb to remove the thermostat box use the tool to push out the temperature control knob remove the thermostat fixing nut and replace the indicator light thermostat and thermostat box etc...

Страница 10: ...not work but the light is working normally please check whether the power cord or the compressor connecting wire is well connected If the refrigerator circuit is normal please check the resistance of...