![Element E3 F Series Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/element/e3-f-series/e3-f-series_installation-instructions-manual_2387318001.webp)
Installation Instructions for
920E3
-
-
HMH AIC FL
Round or Square Type
Adjustable Housing
IC
with Toroidal Transformer for Flanged Trims
E3_F_-
_
HAIM
1.5
HALOGEN MR
ROUND SQUARE FLANGED
16 -
/
G
P
I
:
ENERAL RODUCT NFORMATION
This product can be dimmed with a low-voltage magnetic
dimmer.
For insulation applications above R25, no branch circuits
allowed.
This instruction shows a typical installation.
1
HOUSING CLASP
HOUSING
1B
INNER ADJUSTABLE BAR
OUTER ADJUSTABLE BAR
TAB
STOP POINT
3
3
NAIL
2
Slide the inner adjustable bar completely through the
three housing clasps. Make sure the nail is on top.
Slide and push the outer adjustable bar completely onto
the inner adjustable bar so that the tab clicks into place
behind the stop point. This will prevent the adjustable bars
from coming apart.
Repeat steps 2 & 3 for the other side of the housing.
2
3
4
Install the Housing with Adjustable Bars
1A
BREAK OFF
AND DISCARD
¾” or thicker
½” to ¾”
LEAVE TAB
IN PLACE
Keep Tab for ceiling ½” to ¾” thick.
When using adjustable hanger bars with ½” to ¾” thick
ceilings, leave the tab of the hanger bars in place.
Break off Tab for ceiling ¾” or thicker.
When using adjustable hanger bars with ¾” or thicker
ceilings, remove the tab by bending it at the perforation.
1
NOTE:
Skip this section if installing the housing
with butterfly brackets.
CAUTION RISK OF FIRE
-
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.