These instructions are an integral part of the product. Please read it carefully before you install the product. The safety instructions and all other information included in this installation
manual must strictly be observed. Should you have any further questions, please contact LEDON before starting installation. Keep these instructions for future reference.

safety

 

instructions

:

1.  

This installation requires expert knowledge and must be effected by a qualified specialist, such as an electrical engineer or a similarly qualified person.

2.  

For installation and operation of this product, national and international regulations must be observed.

3.  

During installation, separate a security area in a radius of 6 m.

4.  

Use only appropriate fastening materials and a suitable foundation to install the luminaire. Please observe the specified clamping force and torque values.

 

If necessary, consult an expert.

5.  

Install the luminaire only when there is no wind.

6.  

Due to the product’s weight and dimensions, non-compliance with the instructions may result in material damage and risk of injury. Remember to take security measures

 

and take due note of all items listed in this manual.

7.  

Take care not to pinch or clamp any cables when you install the luminaire.

8.  

Do not use any other components than those supplied with the luminaire. Use only original parts for installation or maintenance work.

9.  

Only the spare parts specified by LEDON may be used, and they may be replaced by LEDON or a qualified partner only.

10.  

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

 

Caution. Risk of electric shock (IEC 60417-6042:2011-11).

11.  

If any changes to the luminaire are made at a later date, the person performing such changes will be considered the manufacturer.

12. 

Any software updates must be coordinated with LEDON.

13. 

The luminaire is nearly maintenance-free. The screw tension force (150 Nm, item 1 M16 safety nuts) has to be checked annually; the LED lens must be cleaned with a

 

moistened microfiber cloth and the PV modules with a glass cleaner.

14.  

The entire pole is made of conductive material (aluminum) and is electrically conductive connected to the ground tube and therefore does not need to be grounded

 additionally.
15.  

Do not short-circuit the battery.

16.  

Any defective components must be disposed of in compliance with local conditions and regulations. Discharge the battery pack before disposing.

17.  

In case of malfunctions or damage, please contact LEDON. 

operating

 

instructions

:

18.  

Do not install the luminaire in places where local obstacles or shadows cast by trees, mountains, buildings or similar may interfere with the PV modules. Likewise, partial

 

shading of the individual PV modules must be avoided.

19.  

Direct sunlight is preferable.

20.  

The luminaire has been optimized according to your specifications in the online configurator to match the location selected and has the lighting profile defined by you.

21. 

 If it is necessary to store the battery temporarily, request a charger from LEDON to ensure immediate operation.

22.  

FAQs can be found on the last page of this instruction manual.

Содержание LEDON LEDIVA

Страница 1: ...k 9 Only the spare parts specified by LEDON may be used and they may be replaced by LEDON or a qualified partner only 10 The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person Caution Risk of electric shock IEC 60417 6042 2011 11 11 If any changes to the luminaire are made at a later date the person performing such...

Страница 2: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 2 10 Tools required ...

Страница 3: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 3 10 1 Prepare the foundation ...

Страница 4: ...TRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 4 10 2 Push in the battery pack and screw in the drawbars ...

Страница 5: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 5 10 3 Screw on the ground tube ...

Страница 6: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 6 10 4 Fasten the light module to the luminaire ...

Страница 7: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 7 10 5 Cable connection ...

Страница 8: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 8 10 6 Mount the cover ...

Страница 9: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 9 10 7 Push the luminaire into the foundation ...

Страница 10: ...ELEKTRON AG Riedhofstrasse 11 CH 8804 Au ZH 41 44 781 01 11 licht elektron ch www elektron ch solar lighting 903181891 Original Anleitung DEUTSCH Seite 10 10 FAQ ...

Отзывы: