Page 8
ENCLOSURE INSTALLATION
Before mounting the enclosure, the surface has to be checked for flatness, slope and freedom
from vibrations. Mounting must be vertical.
It is important that the door can be clearly seen
from the position of the control through-out its travel.
CONNECTING THE CONTROL AND THE ELEKTROMATEN
®
After the drive and control are fitted they can be connected with a plug-in cable.
The cable
has plugs on each end and for easy fitting. The plugs for motor and control panel are different
and cannot be interchanged.
Cable Description
Motor plug to control Panel
PIN
- Wire-No.
1
-
3
Phase W
2
-
2
Phase V
3
-
1
Phase U
4
-
4
Neutral (N)
5
-
PE
Earth
Limit switch plug to control panel
PIN
- Wire-No.
1
-
5
24V
2
-
6
S 5 aux. limit only for Testing of safety edge system
3
-
7
open - limit
4
-
8
S 6 aux. limit for intermediate Stop or switching contact
5
-
9
close limit
6
-
10
safety circuit common limit
Connection cable
Control panel TS 961
ELEKTROMAT
®
1
2
PE
3
4
8
7
10
9
6
5
16
15
14
10
6
5
4
9
17
8
7
13
12
11
3
2
1
4
PE
- 1
- 2
- 3
- 4
- 5
PIN
- 1
4 -
5 -
6 -
- 2
- 3
PIN
Motor plug
Limit switch plug