Electrical operating instructions

Door control panel TS 961

Software 2.6 (Design and functions subject to change)

51171292 

-

 

f 02.2013

en

Содержание TS 961

Страница 1: ...Electrical operating instructions Door control panel TS 961 Software 2 6 Design and functions subject to change 51171292 f 02 2013 en...

Страница 2: ...USTMENT 13 HARDWARE OVERVIEW 14 WIRING DIAGRAM 15 CONTROL PROGRAMMING 16 Operating mode 17 Functions 17 Reset 18 Maintenance cycle counter 18 MEMORY CHECK 18 SAFETY DEVICES 19 Safety nection for shutt...

Страница 3: ...22 Automatic closing interruption 22 Photo beam for Closing Direction X6 23 Ceiling pull switch Radio control X7 24 Key switch intermediate stop X8 24 Potential free changeover contact X9 25 Maintenan...

Страница 4: ...and gates Safety in use of power operated doors Requirements and left the factory in perfect condition from the point of view of safety To maintain this condition and to ensure safe operation the user...

Страница 5: ...with a permanent mains connection an all pole main switch with appropriate back up fuse must be provided Check live cables and conductors regularly for insulation faults or breakages When a fault is d...

Страница 6: ...7 page 9 LIMIT SWITCH CONNECTION Single limit switches page 10 Check Mains supply page 11 Check Phase rotation page 12 Adjustmemt Limit switch adjustment page 13 The door is ready to work in Dead man...

Страница 7: ...t automatic closing Emergency stop Key switch latching inter mediate stop Signal lamp Connection cable ELEKTROMAT for Motor and mechanical limits NES 11 5 5 3 5 3 3 3 3 Spiral cable for Safety edge sy...

Страница 8: ...easy fitting The plugs for motor and control panel are different and cannot be interchanged Cable Description Motor plug to control Panel PIN Wire No 1 3 Phase W 2 2 Phase V 3 1 Phase U 4 4 Neutral N...

Страница 9: ...Page 9 LIMIT SWITCH CONNECTION Plug in system...

Страница 10: ...Page 10 LIMIT SWITCH CONNECTION Terminal version until year 1997 LIMIT SWITCH CONNECTION Single limit switches M 3 M 3...

Страница 11: ...1 Fig 2 Fig 3 Fig 5 Fig 4 asymmetric winding symmetric winding Important note The bridge must be fitted into the right terminal otherwise the print could be destroyed 400V mains supply 1 5 1 6 230V m...

Страница 12: ...h through electric shock Before changing phase rotation the mains supply must be switched OFF Three phase 3 x400 V AC N PE Star connection Three phase 3 x230 V AC PE Delta connection Single phase 1x23...

Страница 13: ...se position limits have been set the safety limits are automatically pre adjusted Eventually fine adjustment could be required Please see Mechanical Operating Instruction After reaching the final open...

Страница 14: ...9 L1 fused with F1 1A MOT Motor connection 1 8 N NES Mechanical limit connection only with 3 x 400V N PE und 1 x 230V N PE Internal push button X2 Safety edge system and pass door plug X3 Emergency pu...

Страница 15: ...diate stop Warning light Aux contact Terminal box Bridge passor slack wire switch contact passor slack wire switch contact end of line resistor 1K2 end of line resistor 8K2 Terminal box Bridge Termina...

Страница 16: ...til display 00 Press selector and 1 Enter programming Mode Press selector switch for 3 sec until display 00 2 Chose program and confirm Turn selector press selector 3 Adjustment Turn selector 4 Memori...

Страница 17: ...se for external pushbutton function only dead man close Press selector Commands door travels to Open or Closed position during closing door Stops and re opens Step by Step function X7 only Ceiling pul...

Страница 18: ...ld be dis played as follow M 1 000 000 H 100 HT 100 000 Z 10 ZT 10 000 E 1 T 1 000 2 Chose program and confirm 01 99 correspond from 1 000 up to 99 000 Count down cycles Counter adjustment Display app...

Страница 19: ...tance evaluation 8K2 with normally open safety edge contact Typ 3 Optical safety edge Vitector Mounting the spiral cable A bush is provided on both sides of the control box for mounting the spiral cab...

Страница 20: ...recognizes the function of the safety edge If the pressure switch has not been activated the control goes into fault mode and the system works only in DEAD MAN function in downwards direction Fault i...

Страница 21: ...S With menu 2 1 the function of the safety edge system can be chosen Function of the safety edge system Function Reaction following the activation Active safety edge stop De activated safety edge no r...

Страница 22: ...n after the pre adjusted time Important note The timer can be interrupted by pressing internal pushbutton stop button when the shutter has reached a limit position With a new command UP DOWN the timer...

Страница 23: ...time interruption The time delay is cancelled and re made Closing Door Stops and re opens fully Important note The load on the 24 V DC power supply may not exceed 150 mA The light barrier is used in a...

Страница 24: ...operation Shutter closed Shutter moves to fully open Shutter moving upwards No reaction Shutter open Shutter moves to fully closed position Shutter intermediate position open Shutter moves to fully op...

Страница 25: ...vices 230V AC max 1A 24V DC max 150mA At a short circuit or overload at the 24V DC supply the display is off Maintenance cycle counter Free adjustable maintenance cycle counter Menu 8 5 makes it possi...

Страница 26: ...heck the safety edge is connected correctly or the wrong type has been selected in the program Light barrier activated Check the light barrier has been fitted properly or whether the connecting cable...

Страница 27: ...ted or defect Check the proper safety edge function or whether the supply cable is interrupted Check safety edge and connecting cable are not broken Safety open or close limit operated Turn mains supp...

Страница 28: ...tching OFF or change the control Internal fault report Reset by switching OFF or change the control RAM Fault Reset by switching OFF or change the control Internal control fault Reset by switching OFF...

Страница 29: ...ca 15 VA without motor and ext 230V External supply 1 230V via L1 and N safety fuse F1 1A t External supply 2 24V DC uncontrolled max Load 150mA Protected via electronic fase Inputs 24V DC typ 10mA si...

Страница 30: ...we recommend a replacement for control boards in use after doors having reached their confirmed lifetime cycles Coherence between power and amount of cycles for ELEKTROMATEN describes diagram bellow...

Страница 31: ...chinery Authorised representative for the compilation of the relevant technical documents internal EU address Dipl Ing Bernd Synowsky Documentation representative Incomplete machines within the meanin...

Страница 32: ...nterrupting and re making light barrier closing after 3 sec Can be interrupted by a separate switch Supply for external devices 230V at 400V 3 with N up to 1A load 24V DC up to 150mA load Plug connect...