background image

Backlit display

After you press any button, 
the display is backlit automatically 
for at least 5 s.

Controls

turning 

= change of temperature setting

short press 

= selection (entry) confi rmation

   

= rquick change of required 

   

temperature or program (see page 8); 

   

viewing other information (see page 8) 

long press 

= step back (only in the CONST mode, 

   

see page 5)

press 

= opening the main menu or returning 

   

a step back

The GSM aerial 

is included in the 

packing (can be replaced by 
an external one 
with higher sensitivity).

1

2

4

6

7

8

9

10

12

13

14

15

16

17

3

5

11

18

Connector for external sensor

can be used with sensors CT04-10k 
(order No. 0012), CT01-10k (order No. 
0015) or CT02-10k (order No. 0013)

Connector for power supply No. 1

for the AD05-jack power supply 

(included in the packing)

Connector for power supply No. 2

for power source installed in a wiring 
box (not included in the packing)

SIM card holder

space for inserting the SIM card 
(the SIM card is not included in the 
packing)

Backup batteries room

to backup the time running, always use 
rechargeable batteries of the AA/R6 
type (not included in the packing)

1

ROOM THERMOSTAT

WITH GSM MODULE

A sophisticated thermostat which can be remotely controlled by means of SMS messages from your mobile phone. 
The thermostat includes two devices, temperature controller and GSM module, which co-operate, thus increasing the comfort 
of the heating system control. Simple control elements are used for setting; intuitive navigation in the selected language 
(CZ/PL/EN/DE/RU/SVK). Remote control is executed by means of brief SMSs which enable you, for example, to change the 
required temperature or turn off the system. This unique thermostat with a big backlit display and intelligent PID-control offers 
a wide variety of usage in residential houses, offi ces as well as recreation areas.

DESCRIPTION

LCD DESCRIPTION

1.  Current day (in the Prog mode, 
 

selection of days to be 

 programmed)
2.  Heating on indication
3.  Current room temperature
4. Anti-freeze 

temperature

5.  Modes for setting programs 
 

(PROG) and constants (CONST) 

 

(page 4 and 5)

6.  Automatic mode (page 3)
7.  Manual mode (page 3)
8.  Clock setting mode (page 3)
9.  Holiday mode (page 3)
10.  Permanent shut-off (page 3)

11.  Summer mode (page 6)
12.  Boiler inspection indication 
 (page 

8)

13.  External sensor connection 
 

indication (see page 7)

14. Current time
15.  Current date (various parameters 
 

in the CONST mode; for details, 

 

see page 5)

16.  Status line, dynamically changing 
 

according to the process running

17.  Key lock indication (page 8)
18.  Low battery indication

Type AD05-jack 
5V/ DC, 2.5 A

Open the SIM card 
holder and insert the 
SIM card in the direction 
indicated; then close the 
holder again.

Type CT04-10k
silicone conductor, length 
3 m for measurements 
up to 99 °C, including 
connector

GST type – external 
9 dBm, SMA connector 
(not included in the 
packing); can be 
purchased separately, 
order No. 1330, 
on www.elbock.cz.

Use the type:
5V / DC, 2,5 A
(SELV)
MIND THE 
POLARITY!!

PT32 GST

PT32 GST

RESET

press this button with MENU butto 
for restoring to default settings
(see page 8)

0 V

+5 V

Содержание PT32 GST

Страница 1: ...s are used for setting intuitive navigation in the selected language CZ PL EN DE RU SVK Remote control is executed by means of brief SMSs which enable you for example to change the required temperatur...

Страница 2: ...he main circuit breaker and test the thermostat for correct connection see page 3 TEST 11 Upon the rst start or reset the thermostat shows the SET CLOCK ENTER PIN messages set the current time and dat...

Страница 3: ...urn from the holiday Change the values by turning the button and con rm each change by pressing the button After making the settings press the button to return to the basic screen Note The holiday mod...

Страница 4: ...number is ashing on the display Turning the button choose the program which you want to change and press the button to con rm Turning the button choose the number of days to be programmed you can prog...

Страница 5: ...7 Choose within the range from 15 C to 39 C by 0 5 C Set the value by turning the button and press the button to con rm PID control set by default Choose the type of control by turning the button and...

Страница 6: ...ou need not consider when to switch the heating on in order to be warm when getting up in the morning without heating unnecessarily long in advance You just program the time at which you want the desi...

Страница 7: ...igits stepwise con rm each setting with the button GSM TEST 14 12 The external sensor can be used for 1 control according to the room temperature the sensor is located in the room option 2 control acc...

Страница 8: ...the NO set by default 1 1 2032 set by default 19 PASSWORD not set by default It is used for locking the constants related to the given control settings Suitable for service technicians After a numeri...

Страница 9: ...minable or no signal detected 1 worst level 5 best level of signal REQUIR TEMP Information on the desired temperature preset PROGR 3 PERIOd 2 Information on the program preset e g 3 and the time inter...

Страница 10: ...MANU Send SMS Off The thermostat switch off the heating system and send a reply SMS with information about the current state of the hea ting system to permanently shut down the system Send an SMS eg...

Страница 11: ...11 Notes...

Страница 12: ...ial free contacts Working temperature 0 C to 40 C Dimensions control by means of a mobile phone 9 weekly programs 6 temperature changes per day programming by 10 minutes and 0 5 C programming day by d...