ELEKTROBOCK PocketHome PH-TS20 Скачать руководство пользователя страница 7

7

PROG FUNCTION 

program defining

- press 

and by 

button select 

PROG 

function

(PROGRAMMING)

confirm by pressing 

- by pressing 

select the day, which should be 

programmed according to following table:

i

Fce

d:1 Monday
d:2 Tuesday
d:3 Wednesday
d:4 Thursday

d1:5 Monday to Friday    
d6:7 Saturday to Sunday 
d1:7 whole week

d:5 Friday
d:6 Saturday
d:7 Sunday

TABLE: SELECTION OF DAY TO BE PROGRAMMED

- when the day is selected, press 

and symbol 

1:U1

is 

displayed, so that you can set the first time interval

- by pressing 

set the time of the first change 

(min. step: 10min.)

- by repeated pressing of

assign required temperature 

to this time

- again confirm by pressing

and the display automatically 

shows symbol 

1:U2

for the second time interval in the first day.

P

i

i

- this procedure should be repeated until all time intervals (max.6) are set and 

afterwards leave the programming mode by pressing 

.

- select 

AUTO

function and the socket starts to function according to defined 

program. 

Fce

Indication of socket condition in autonomous mode:

symbol AUTO(or MANU) on the display IS ALIGHT

= connected appliance is

SWITCHED ON

symbol AUTO(or MANU) on the display FLASHES

= connected appliance is

SWITCHED OFF

EXAMPLE 

definition of weekly program 

1, Set       for 18°C (PA:r2)
2, Set       for 23°C (PA:r3)
3, Set  

P

for 25°C (PA:r4)

4, Select programming of whole week 

d1:7

(Prog)

5, Assign the time of 6:00 and        temperature to 

17:U1

6, Assign the time of 9:00 and        temperature to 

17:U2

7, Assign the time of 13:00 and      temperature to 

17:U3

8, Assign the time of 16:00 and      temperature to 

17:U4

9, Assign the time of 19:00 and  

P  

temperature to 

17:U5

10,Assign the time of 22:00 and      temperature to 

17:U6

11,

Leave the programming mode by pressing 

and select 

AUTO 

func.

Fce

representation of 

program course on LCD

Содержание PocketHome PH-TS20

Страница 1: ... communication on 433 92 MHz It switches on off connected appliance according to required temperature Current temperature measuring with built in sensor Central unit PH CJ37 acts as a superior component Power supply 230 V 50 Hz Operating instructions PH TS20 version 10 07 NEW FEATURES SUMMER MODE FOR SWITCHING THE AIR CONDITIONER ON OFF ...

Страница 2: ... t current time temperature CL O tE P sum of operating hours SU MA and day dE n setting of temperature time functions browsing socket for controlled appliance DISPLAY DESCRIPTION indication of operational mode or selected function indication of time temperature indication of temperatures comfort economy party indication of set time and temperature program displayed only in autonomous mode 2 i Fce ...

Страница 3: ...e insertion to PH TS20 socket to be installed in areas with relative humidity lower than approx 95 It is not necessary to set the time as it is synchronized automatically with central unit PH CJ37 Current time is sent to all sockets at each time change central unit displays TS It applies also to the connection of PH CJ37 to PC press by means of select function for socket activation UA dr and confi...

Страница 4: ...N When the socket is activated in the system within UA dr mode see p 3 each socket is gradually assigned with address from 1 to 255 This address cannot be changed but the socket can be deactivated from PocketHome system press by means of pressing the function for parameters setting PA r and confirm by pressing by means of select parameter PA r8 and again confirm by by means of it is possible to de...

Страница 5: ...for manual setting of temperature selected by or by buttons the temperature will be constant up to the next change of mode CLO setting of current day and time PROG programming mode PAr setting of parameters constants OFF in this mode the socket is permanently switched off UAdr mode for socket activation in PocketHome system P Fce Note If no button is pressed in 2 minutes the socket returns to its ...

Страница 6: ...ct in inverse way than in the mode for heating if PA r5 0 5 and required temperature is 23 C the socket switches on at the temperature of 23 5 C by pressing select mode then press button i i P 6 PA r5 HYSTERESIS factory setting 0 5 C PA r5 is showed on the display confirm by and by pressing buttons set hysteresis in the range from 0 1 C to 2 C again confirm by pressing i i HYSTERESIS temperature d...

Страница 7: ...epeated until all time intervals max 6 are set and afterwards leave the programming mode by pressing select AUTO function and the socket starts to function according to defined program Fce Indication of socket condition in autonomous mode symbol AUTO or MANU on the display IS ALIGHT connected appliance is SWITCHED ON symbol AUTO or MANU on the display FLASHES connected appliance is SWITCHED OFF EX...

Страница 8: ...e are showed alternatively on the display To cancel this function press button and select different mode with using of buttons Fce i Fce OFF FUNCTION permanent switching off It serves for keyboard blocking as a protection against unauthorized handling Press button then simultaneously press and now the keyboard is blocked the buttons are inoperative Message LOC LOCK is shortly displayed on the disp...

Страница 9: ...S SOON AS THE TEMPERATURE DROPS UNDER REQUIRED TEMPERATURE THE PH TS20 SWITCHES THE APPLIANCE ON SUITABLE FOR DIRECT CONTROL OF FOL LOWING APPLIANCES ELECTRICAL TUBULAR RADIATORS ELECTRICAL HEATING PLATES DIRECT HEATING BODIES VENTILATORS AIR CONDITIONERS WITH CENTRAL UNIT PH CJ37 IT IS POSSI BLE TO MONITOR CURRENT TEMPERATURE AND CONDITION OF CONNECTED APPLI ANCE AND TO SEND REQUIRED CHANGES OF T...

Страница 10: ...by MADE IN CZECH REPUBLIC Send the socket for guarantee and after guarantee service to manufacturer s address ELEKTROBOCK CZ s r o Blanenská 1763 Kuřim 664 34 Tel fax 420 541 230 216 www elbock cz in compliance with RoHS Pb Pb LEAD FREE ES DECLARATION OF COMPLIANCE We ELEKTROBOCK CZ s r o herewith declare that the PH TS20 product is in compliance with princi pal requirements and further respective...

Отзывы: