2.3.2 Preparation
Mains connection for a PSI 9000 2U series device is done via the included 2 meters long 3 pole mains cord. In
case a different AC wiring is required, make sure that the other cable has at least a cross section of 2.5 mm² (AWG
12) is used.
Dimensioning of the DC wiring to the load/consumer has to reflect the following:
•
The cable cross section should always be specified for at least the maximum current of the
device.
•
Continuous operation at the approved limit generates heat which must be removed, as well as
voltage loss which depends on cable length and heating. To compensate for these the cable
cross section should be increased and the cable length reduced.
2.3.3 Installing the device
•
Select the location for the device so that the connection to the load is as short as possible.
•
Leave sufficient space behind the equipment for ventilation, but minimum 30cm for hot air
exhaust
A device in a 19” housing will usually be mounted on suitable rails and installed in 19” racks or cabinets. The depth
of the device and its weight must be taken into account. The handles on the front are for sliding in and out of the
cabinet. Slots on the front plate are provided for fixing the device (fixing screws not included).
With all models of this series, mounting brackets are included to convert the front plate from a 19” to desktop.
In order to do that, the 19” mounting brackets can be removed after loosening the screws on the front grips and
replacing them by included pieces, or vice versa.
Acceptable and inacceptable installation positions:
Standing surface