55
Make sure the sound and tone are not shut off. Check the settings unit. Check the loudspeaker
inside the Control Unit. See Section 4.1.4
10. APPENDIX
10.1 CERTIFICATE OF EXPERTISE
Certificate of Expertise, certifies that the
ThruScan
taken, in random
from the production line of Elektral® A.S, conforms to the general
test criteria and matches the standards envisioned throughout the
world.
The Magnetic Field Strength of
ThruScan
, appears much lower than
have been stated by FDA. With the
VLF
technology
,
with its special
Rx, Tx coils design and programming which minimize nil points. Thus
it has an improved detection capability in comparison to its
counterparts. It is further certified that it complies with the related
instructions of NILECJ and FDA.
ThruScan
is compatible with VDE standards for noise radiation.
Furthermore, it is certified that
ThruScan
sX-i/sX-WP comply with IP
65;
ThruScan
sX/s15-i/sX-i comply with IP 44, other models could
optionally comply with IP65 when requested.
The best technological components were used for your
ThruScan
and much attention was paid for
the certification of these components that were as in EU and CE directives.
10.2
SRC-SCADA REMOTE CONTROL
It is very easy to use the SRC-SCADA Remote Control Software. In
this Windows based software, there is a “?” icon next to every
button, to “
HELP
” the function of the button.
In Section 10.2.1 you may see the
ThruScan
s3/s6/s9 SRC SCADA
Software, and in Section 10.2.2
ThruScan
sX/sX-WP/s15-i/sX-i,
SRC SCADA Software user manuals.
10.2.1
ThruScan
s3/ s6/s9 SRC-SCADA Remote Control Pro gram User Manual
Please enter your Registration Code for the activation of your SRC-SCADA Remote Control Programmer. You
can have your Registration Code from your dealer by e-mail or telephone.
1.1-
Language
- Select your language from “Setting” window.(English, German, Spanish, Turkish)
1.2-
Connection –
To work with a metal detector you need to connect it to a serial port via the cable. To make the
program, please make sure what port you are using, select the "Com Port" and choose COM1 to COM4.
If the
communication is performed by Telephone Lines then the com-port of the modem should be selected
visually.
You can check several ports simultaneously for the right communication.
1.3-
If the communication would be done by telephone lines; then the phone number should be entered to “
Phone
Number
” window and pressed “
Dial
”. There is no difference between local (in house), domestic or international
communications.
1.4-
Selection of GATE NO
- You have to give index number for each walk-throughs from 1 to 16.
(Note: All
ThruScan
s3/s6/s9 number-1 at the factory out-put)
(Note: During organising the network; When you communicate with selected
ThruScan
s3/s6/s9, you should
disconnect the other Magnetic Walk-Thru Metal Detectors from your network ! )
To change the
ThruScan
s3/s6/s9
’s index number: (Only one
ThruScan
s3/s6/s9 has to be connected to the
network)