There are two options for the location of the ClearVis Flow Sensor:

4. 

The “BEST” location for the ClearVis Flow Sensor is after the Canister output 
with at least 12” of straight hose before and after the Flow Sensor.  
The ClearVis Flow Sensor can also be installed on the pressure side
of the pump. 

5. 

An “ACCEPTABLE” location for the ClearVis Flow Sensor is on the output of  
the ElectroStrainer Canister with at least 12” of straight hose after 
the Flow Sensor.  

                                       

All seawater flowing through the ElectroStrainer 

Canister Assembly must flow through the Flow Sensor. DO NOT split 
or divert seawater before the ClearVis Flow Sensor as this will tell the 
Control Unit to generate an incorrect amount of chlorine.

6. 

Connect threaded male or female PVC hose connectors to ElectroStrainer 
Canister, and/or flow sensor as shown in picture 4 or 5.

7. 

Use thread sealant without PTFE on all connections. 

                                       
                                       

PTFE should not be used on plastic parts. Avoid over 

tightening plastic parts they may crack and result in sinking the vessel. 

                      

8. 

Use two hose clamps, reversing the clamps, over flexible hose connections.

9. 

Add flexible hose hanger, hose strap or hose support bracket within 12” of 
ClearVis Flow Sensor.  Make sure the ClearVis Flow Sensor is supported.  

U.S. Patent No. 11,027,991 and other U.S. and Foreign Patents Pending

ElectroStrainer Canister Installation

12

Canister and Flow Sensor

 

WARNING

BEST:  12” of straight hose before and after Flow Sensor

ACCEPTABLE:  Flow Sensor at ElectroStrainer output with 12” 
of straight hose after Flow Sensor

10

Flow 

Sensor

Support 

weight of hose

4

9

10

Support 

weight of hose

Flow 

Sensor

5

9

WARNING

Содержание ElectroStrainer ES-150

Страница 1: ...InstallationManual Models ES 200 ES 150 ElectroStrainer System 888 384 8881 952 475 8084 support electrosea com www electrosea com ...

Страница 2: ...is any liability assumed for damages resulting from the use of this product and information contained herein 1 Table of Contents Introduction Table of Contents 1 ElectroSea and ElectroStrainer System 2 Components 3 Safety and Pre Installation Descaling 4 Optimal Performance Maintenance Optimal Performance and Strainer Flow Alert 5 Cell Indicator 6 Installation Overview Electrical Connection Overvi...

Страница 3: ...e in a sea strainer and completely redefines seawater system maintenance ElectroStrainer is a Biofouling Prevention Device ElectroStrainer continuously creates a safe and effective level of chlorine to protect your entire seawater system ElectroStrainer contains a Cell with a proprietary mixed metal oxide coating when electrified it acts as a catalyst to generate chlorine naturally from the seawat...

Страница 4: ...ounting Bracket 2 Machine Screws M5 Round Head 3 Machine Screws M6 Round Head 1 Lock Nut M6 1 Machine Screws M8 Round Head 8 Mounting Screws 12 x 1 25 3 2cm Flat Head 1 Chlorinated Return Line Tubing 1 Return Line Tee Fitting 1 Return Line Valve 4 Return Line Hose Clamps 1 Strain Relief Clamp for Return Line Tubing 1 Optional Return Line Canister Cap Components 3 Major components shown above 1 Con...

Страница 5: ...tion descaling ensures any existing biofouling that has accumulated on the interior seawater lines are removed If seawater lines are impacted with barnacles and marine growth then ElectroSea recommends professional descaling prior to installing the ElectroStrainer System By starting with descaled and clean seawater lines you will realize the full benefit of the ElectroStrainer System For new vesse...

Страница 6: ...will continue generating chlorine even after a Strainer Flow Alert occurs If a Strainer Flow Alert occurs 1 Check vessel intake screens for blockage or debris 2 Check seawater pump output impeller or other causes of low flow 3 Check ElectroStrainer basket for debris seaweed or mud Optimal Performance Constant Chlorinated Seawater Flow The ElectroStrainer System should be powered ON and have seawat...

Страница 7: ...shwater run off Low salinity is the most frequent cause of the CELL Indicator ElectroStrainer will not display CLEANING or generate chlorine while vessel is operating in freshwater RESOLUTION Vessel returns to seawater with adequate salinity ElectroStrainer Cell Cable The ElectroStrainer Cell cable and connections must not be spliced cut compromised or damaged Inspect the Control Unit to Cell cabl...

Страница 8: ...d Cable CBL01 CC EXT 20FT 20 6 1m Cell Extended Cable DO NOT cut extend or splice the Cell cable Longer Cell cables are available from ElectroSea DO NOT connect multiple Cell cables together The Cell Extended Cables in the table below show the total cable length from the Control Unit to the Cell Modification of ElectroStrainer Cell cable will impair operation OPTIONAL CABLE ACCESSORIES NOTICE NOTI...

Страница 9: ...the Warranty 8 U S Patent No 11 027 991 and other U S and Foreign Patents Pending Installation Overview 8 Seawater Connection Overview 1 Locate the vessel s seawater intake pump strainer if existing and seacock shut off valve Turn OFF ALL seacock shut off valves in the seawater circuit at or below the water line This includes any output seacocks to prevent back siphoning 2 The Canister Assembly sh...

Страница 10: ... Unsecure the pressure ring by turning the wing nuts counterclockwise 3 Remove the Cell Assembly Lift straight up by the black plastic cover Do not lift or pull on the cable Set the Cell Assembly aside in a safe location Remove the strainer basket Now you can work just with the Canister for mounting 1 2 2 Remove the pressure ring 3 ...

Страница 11: ...g WARNING OPTION B Side Mounting 1 Mount Level 1 Mount Canister to flat interior engine room surface 2 Insert 3 12 mounting screws into base tab to secure the Canister 3 Donotscrewthroughhullofboat WARNING 1 Attach Top mount brackets with 2 M5 screws 2 Attach Bottom bracket with 2 M6 screws front side or 1 M8 screw back side 3 Secure to stringer or other appropriate load supporting vertical surfac...

Страница 12: ... recommended that thread sealant without PTFE is used The ClearVis Flow Sensor measures the velocity of seawater using speed of sound technology It is preferable to have 12 30 5cm of straight hose before and after the ClearVis Flow Sensor This decreases seawater turbulence and improves the speed accuracy and precision of the ClearVis Flow Sensor measurement DO NOT place a 90 elbow or other flow re...

Страница 13: ... Connect threaded male or female PVC hose connectors to ElectroStrainer Canister and or flow sensor as shown in picture 4 or 5 7 Use thread sealant without PTFE on all connections PTFE should not be used on plastic parts Avoid over tightening plastic parts they may crack and result in sinking the vessel 8 Use two hose clamps reversing the clamps over flexible hose connections 9 Add flexible hose h...

Страница 14: ...urn line should be connected from the pressure side of the pump to the Canister Assembly s 90 degree fitting located under the inlet port 2 Connect this chlorinated return line with a tee fitting and ball valve to the pressure side of the pump Note The source for the chlorinated return line must be after the seawater pump on the pressure side and after the ClearVis Flow Sensor 3 Connect the chlori...

Страница 15: ...trainer basket Make sure the lid key is aligned with the Canister Then insert the Cell Assembly into the Canister DO NOT use chemicals acids descaling solutions or zincs in the ElectroStrainer Canister or on the Cell This will damage the Cell 4 Add the pressure ring to the top of the Canister Bleed excess air from the Canister then tighten down the wing nuts evenly Do not use tools to perform this...

Страница 16: ...he vessel Connect the RED and YELLOW wires of the Power Cable to this source according to the appropriate electrical standards i e ABYC Connect the Power Cable A to the Control Unit Control Unit to Canister Connect the Cell cable B between the Control Unit and the Canister Control Unit to ClearVis Flow Sensor Connect the Flow Sensor cable C to the Control Unit and the Flow Sensor Canister Bonding ...

Страница 17: ...24VDC Power Consumption Max power 100 watts Typical power 50 watts Max power 100 watts Typical power 50 watts Internal circuit breaker 10 amps 10 amps Cables included Power 20 6 1m Cell 20 6 1m Flow Sensor 20 6 1m Power 20 6 1m Cell 12 3 7m Flow Sensor 12 3 7m ElectroStrainer Canister Dimensions L x W x H 9 48 x 8 88 x 9 67 inches 240 79 x 225 53 x 245 58 mm 8 20 x 7 74 x 9 63 inches 208 28 x 196 ...

Страница 18: ...al end user purchaser of a Product directly from ElectroSea or an authorized ElectroSea Dealer a Direct Purchaser or 2 The original end user purchaser of a new vessel in which a new Product was installed by the manufacturer a Vessel Purchaser 3 This Limited Warranty is not transferable How Long Coverage Lasts the Warranty Period This Limited Warranty only applies for a two year period the Warranty...

Страница 19: ...ber the type and length of vessel on which the Product is used and a reasonably complete description of the problem you are having ElectroSea may require that you send the Product to ElectroSea at your cost for examination If your claim is covered by this Limited Warranty ElectroSea will pay the cost of sending the Product as repaired or a replacement Product to you No Other Express Warranties Thi...

Страница 20: ...750074 005 888 384 8881 952 475 8084 support electrosea com www electrosea com ...

Отзывы: