CLEARLINE Location and Mounting
•
Mount the CLEARLINE Control Unit (1) on a bulkhead in the engine room using four #10
stainless steel Mounting Screws provided. CLEARLINE is designed for marine engine rooms
with a maximum environmental temperature of 50
°
C (122
°
F). Do not mount CLEARLINE in
an area that receives excessive heat.
CLEARLINE to 24VDC Power Supply
1.
Power OFF the CLEARLINE Control Unit (2) before beginning the wiring process below.
2.
Locate an always on, 24VDC power source on the vessel. Connect the
RED (+)
and
YELLOW (-)
wires of the Power Cable to this source according to the appropriate
electrical standards (i.e. ABYC). Connect the Power Cable (A) to the CLEARLINE Control Unit.
Failure to Power OFF the CLEARLINE Control Unit during the wiring
process could result in damage to the CLEARLINE System.
CLEARLINE to ClearCell
•
Connect the ClearCell cable (B) between the CLEARLINE Control Unit and the ClearCell.
CLEARLINE to Flow Sensor
•
Connect the Flow Sensor cable (C) to the CLEARLINE Control Unit and the Flow Sensor.
ClearCell Bonding
•
Connect vessel bonding wire to ClearCell bonding terminal according to appropriate
bonding standards (i.e. ABYC).
Failure to bond ClearCell will void Warranty.
NOTICE
CLEARLINE Control Unit Installation