Modes and Features
7
7
U.S. and Foreign Patents Pending
The Pump Mode should be set up during the installation process. Refer to the table below to verify the Pump Mode is set correctly. Use the Up or Down arrow to
select Pump Mode.
Mode
Description
Wiring
Required
Pump Sense Not Used
Pump sensing is not being used. This is the factory default mode.
(Note: If your vessel does not have
dual pumps and/or cannot be connected to CLEARLINE’s automatic pump cycling feature, then set Pump
Mode to “Pump Sense Not Used”).
No
Pump#1 and Pump #2
Alternating
Two seawater intake pumps are wired to the CLEARLINE System. Pump #1 and Pump #2 can be alternated
at a specific time duration from 10 minutes to 72 hours. The CLEARLINE System is controlling the ON/OFF
pump operation.
Yes
Pump#1 and Pump #2
Monitors
Two seawater intake pumps are wired to the CLEARLINE System. Pump #1 and Pump #2 can be monitored.
The CLEARLINE System is only monitoring and is NOT controlling the ON/OFF pump operation.
Yes
Pump #1 ONLY Monitor
One seawater intake pump is wired to the CLEARLINE System. Pump #1 is for monitoring only.
Yes
Set Pump Time:
This is an optional feature for vessels that have dual seawater intake pumps that are manually cycled. This feature sets the desired duration of
time that Pump #1 or Pump #2 operates. The Pump Time can be set to 10 minutes, and 1 hour intervals up to 24 hours, 48 hours, and 72 hours.
Use the Up or Down arrow to select Pump Time.
Pump Mode and Time continued
>
-Pump Mode
-Cell
-Pump Time
-Default
-Flow Alert -Update
-Display
-Exit
Pump Time
24 hours
OK to Exit