Operation Manual 

Model CL-2000-X2.0

CLEARLINE

®

 System

Содержание CLEARLINE CL-2000-X2.0

Страница 1: ...888 384 8881 952 475 8084 support electrosea com www electrosea com OperationManual ModelCL 2000 X2 0 CLEARLINE System...

Страница 2: ...assumed for damages resulting from the use of this product and information contained herein 1 Introduction Table of Contents 1 ElectroSea and CLEARLINE 2 Safety Considerations 2 System Features User I...

Страница 3: ...arine electrochlorination system that prevents biofouling and barnacle growth in your vessel s seawater lines CLEARLINE keeps your air conditioners chillers and refrigerators operating at maximum flow...

Страница 4: ...r Interface Features and Functions 1 Power on CLEARLINE The Control Unit will complete a diagnostic self test and then the green POWER light will be illuminated 2 The main status screen will be displa...

Страница 5: ...CLEARLINE CL 2000 X2 0 should not be used with flow rates 75 GPM 283 9 LPM Pump Mode Optional feature for vessels with two seawater intake pumps that require manual alternating of the pumps on a regul...

Страница 6: ...Flow 1 3 GPM 3 8 11 4 LPM or No Flow 0 GPM Power ON and Start up Delay Auto Mode CLEARLINE Menu Cleaning XX GPM Auto Set Backlight Contrast or Units The LCD display backlight contrast and imperial met...

Страница 7: ...nd or to automate the seawater pump alternating process This optional feature is useful for vessels that have two seawater intake pumps that require scheduled manual cycling The Pump Mode and Time fea...

Страница 8: ...minutes to 72 hours The CLEARLINE System is controlling the ON OFF pump operation Yes Pump 1 and Pump 2 Monitors Two seawater intake pumps are wired to the CLEARLINE System Pump 1 and Pump 2 can be mo...

Страница 9: ...ow Alert occurs 1 Check vessel s strainers and intake grates for blockage 2 Check seawater pump operation 3 Check ClearCell Internal Screen see Pg 10 15 Pump Mode Cell Pump Time Default Flow Alert Upd...

Страница 10: ...run off Low salinity is the most frequent cause of CLEARLINE CELL Indicator CLEARLINE will not display CLEANING or generate chlorine while vessel is operating in freshwater RESOLUTION Vessel returns t...

Страница 11: ...eases seawater flow Before accessing the ClearCell Electrode double check the list of Alerts and Indicators on Pg 8 and 9 because the ClearCell infrequently requires rinsing NOTICE Low Salinity is the...

Страница 12: ...eacock valves in the seawater circuit at or below the waterline This includes any output seacocks to prevent back siphoning Failure to turn OFF ALL seacock valves in the seawater circuit could result...

Страница 13: ...4 Remove the pressure ring by turning the wing nuts counterclockwise 5 Remove the pressure ring 4 5 6 6 Remove the Electrode Assembly by lifting it straight up by the sides of the black plastic top D...

Страница 14: ...r debris in the internal screen DO NOT TOUCH THE SURFACE BETWEEN THE ELECTRODE PLATES OR USE ANY TYPE OF MECHANICAL BRUSH THE CLEARCELL ELECTRODE PLATES CONTAIN A SPECIAL METAL OXIDE COATING THAT WILL...

Страница 15: ...nd the ClearCell canister key and insert it into the ClearCell canister 9 Add the pressure ring and begin tightening down the wing nuts evenly Bleed all air out of the ClearCell canister and then fini...

Страница 16: ...he CELL Indicator is still active then one of the following conditions still persists Water salinity is below 20 parts per thousand ClearCell cable or its connectors has been compromised ClearCell Ele...

Страница 17: ...firmware version c Press and hold the Up Down keys simultaneously for 10 seconds then release the keys once the update begins d During the update the Control Unit is in a locked mode and cannot be use...

Страница 18: ...venting unwanted marine growth barnacles and biofilm in the seawater lines If there are any concerns during the regular inspection noted above then perform a more thorough process Visually inspect all...

Страница 19: ...24VDC 7 Amp Max Peak Current Normal Operating Flow 35 75 GPM 132 5 283 9 LPM Maximum Pressure 70 psi CLEARCELL Size 10 2 inches 26cm height 8 4 inches 21 3cm diameter width CLEARLINE CONTROL UNIT Siz...

Страница 20: ...ical parameters and environmental temperature This is a normal operating mode See Pg 5 for Auto Mode Min Flow The flow rate is 1 3 GPM 3 8 11 4 LPM and is too low to chlorinate seawater The Min Flow i...

Страница 21: ...when conditions are resolved Water Salinity Vessels often encounter brackish or freshwater when cruising inland and from storm run off Low salinity is the most frequent cause of CLEARLINE CELL Indicat...

Страница 22: ...al end user purchaser of a Product directly from ElectroSea or an authorized ElectroSea Dealer a Direct Purchaser or 2 The original end user purchaser of a new vessel in which a new Product was instal...

Страница 23: ...ber the type and length of vessel on which the Product is used and a reasonably complete description of the problem you are having ElectroSea may require that you send the Product to ElectroSea at you...

Страница 24: ...888 384 8881 952 475 8084 support electrosea com www electrosea com 750072 002 REV A...

Отзывы: