Содержание Penta

Страница 1: ......

Страница 2: ...planation you will receive from your installer we urge you to read through this manual This will help you familiarize yourself with the system so that you can take advantage of its many advanced features This booklet should be kept in an accessible location and the system reference guide located in the rear portion of this manual should be filled out If you do not understand any part of this manua...

Страница 3: ...curity zones A zone can be defined as a protected area in your security system Each zone can be protected by one or more detection devices such as motion detectors magnetic contacts glassbreak detectors and shock sensors When one of these detection devices is activated it opens the zone to which it is connected System Monitoring Your security system can be monitored either by a monitoring service ...

Страница 4: ...tem is ready to be armed SYSTEM The System LED blinks to indicate that new events have been recorded in one of the logs and when displaying additional system information such as bypass mode ARMED The Armed LED lights to indicate the system is armed or in programming mode and flashes during the exit delay POWER The Power LED lights up when both AC battery power are OK blinks when the battery is low...

Страница 5: ...ystem operations such as arming and disarming Each user code is four digits long Of the four user codes only User Code 1 has the authorization to program other user codes The default code for User 1 is 1111 This default value must be changed immediately to prevent unauthorized access to your system To program user codes 1 4 1 Press Q 5 2 Enter User Code 1 the Armed and System LEDs flash and the zo...

Страница 6: ...nes are still not secured after the exit delay has ended an alarm will be generated To force arm the system 1 Press Q 8 2 Enter a valid user code the keypad beeps until the end of the exit delay Quick Arming This feature allows you to arm the Penta without entering a valid user code To Quick arm the system 1 Check that all zones are closed the Ready LED lights up to indicate that the system is rea...

Страница 7: ...ypassed the corresponding zone LED lights up 4 Press to exit bypass mode the bypassed zones flash To unbypass a zone 1 Press Q 1 2 Enter a valid user code the System LED flashes and the LEDs of any currently bypassed zones light up 3 Enter the number of the zone to be unbypassed the corresponding zone LED turns off 4 Press to exit bypass mode Note Disarming the system automatically unbypasses all ...

Страница 8: ...Alarm event log 1 Press Q 3 an alarm from a specific zone is indicated by the corresponding zone LED 2 Press to exit the event log Both logs are automatically reset when the system is next armed 3 9 Follow me If your system is not monitored by a central station either the Follow me or Voice message feature is used to inform you that an alarm has occurred When using Follow me the Penta dials the te...

Страница 9: ... of short beeps to indicate Zone Chime OFF Keypad Backlight On Off To toggle the backlight of any keypad On or Off Press and hold down for more than 2 seconds 3 11 Testing the System Electronics Line recommends that you test your system at least once a week Walk Test Walk test mode enables you to test peripheral detection devices such as PIR detectors and magnetic door contacts In this mode when a...

Страница 10: ...__________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ __________...