Max Displayed Range (Unit Only):
Fuel Flow:
199.9 Gals/Hr or 162.0 br Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.
Fuel Remaining:
999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.
Fuel Used:
999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.
Time to Empty:
19 hours 59 minutes
Fuel Pressure:
1.0 to 99.8 PSI (Readings below 1.0 PSI will be displayed as 00.0 PSI)
Pilot Programmable Modes:
17
RS-232/422 Input Ports (FP-5L Only):
Single Line Receive Method: RS-232C, RS-423 or 5 Volt Serial.
Dual Line Receive Method:
RS-422 or RS-485.
Protocol:
1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate:
9600
Recieve Format:
Same as King, II Morrow, ARNAV and Trimble.
RS-232/422 Output Port (FP-5L Only):
Transmit Method:
RS-232C Single Line.
Protocol:
1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate:
L 1 = 9600, L 2 = 1200
Transmit Format:
L 1 = King KLN-88, L 2 = Northstar
Fuel Flow Transducer, Standard (FT-60):
Range:
0.6 to 60 GPH
Linearity:
1% (8 to 60 GPH)
K Factor:
Approx. 85,000
Pressure Drop:
1.2 PSI at 30 GPH
4.8 PSI at 60 GPH
Working Press:
200 PSI
Min. Burst Press: 2000 PSI
Temp. Range:
-65'C to 125'C
Fuel Ports:
1/4" Female NPT
Fuel Flow Transducer, Special (FT-90):
Range:
3 to 90 GPH
K Factor:
Approx. 19,500
Pressure Drop:
.31 PSI at 30 GPH
2.8 PSI at 90 GPH
Working Press:
200 PSI
Min. Burst Press: 2000 PSI
Temp. Range:
-65'C to 125'C
Fuel Ports:
1/4" Female NPT
Fuel Pressure Transducer (PT-100GA):
Range:
0 to 100 PSI
Over Press:
300 PSI without damage.
Min. Burst Press: 500 PSI
Temp. Range:
-40'C to 125'C
Material:
303 Stainless Steel
Press. Port:
1/4" Male NPT
Display Modes
Power-up
FLOW
REM
USED
T. to E.
PRESS
Programming
Full Fuel Level
Display in
Gal, br Gal,
Lbs. or Ltr.
Add Fuel
Low Fuel Reminder Alarm
Time to Empty
Alarm
High Pressure
Alarm
Modes
K Factor
Low Fuel Warning Alarm
Low Pressure
Alarm
Filter
Display Update
Time
Loran/GPS
Interface
(FP-5L only)