background image

  3

BEFORE YOU START

CHECK THE VOLTAGE

First  check  the  voltage  shown  on  the  data  plate  (see  rear  view)  to  make  sure  that  the  cleaner  is  of  the  correct  voltage  for  your 
electricity supply. If it is not, do not use the cleaner but refer back to your dealer.

CONNECTING TO YOUR ELECTRICITY SUPPLY

Permanently connected to the cleaner is a mains supply (2-core) cable fitted with a non-rewirable plug incorporating a 13A fuse. 

In the event of the fuse requiring replacement the fuse cover should be removed using a small screwdriver. The old fuse 

MUST

 be 

replaced by a 13A ASTA approved BS1362 fuse or a BSI approved fuse.  The cover must be replaced before the plug is used again. 

In the event of loss of the fuse cover, replacements can be obtained from your Electrolux Retailers and must be of the same colour 

as indicated by the coloured insert on the base of the plug. 

If difficulty is experienced in obtaining a replacement, contact Electrolux on 08706 055055.

In no circumstances must the plug be used without a correct fuse cover fitted.

If the plug that is fitted to your appliance is not suitable for your socket outlet, it must be cut off and the appropriate plug fitted.

Remove the fuse from the cut off plug.

The cut off plug should then be disposed of to prevent the hazard of shocks in case it should be plugged into a 13 amp socket in 

another part of your home.

The wires in the mains cable of this appliance are coloured in accordance with the following code:

   Blue: Neutral.  Brown: Live.

As the colours of the wires in the mains cable of this appliance may not correspond with the coloured markings identifying the terminals 

in your plug, proceed as follows: 

The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

If using a three-pin plug, do not make any connection to the terminal marked with the letter E or by the earth symbol or coloured green 

or green-and-yellow. This cleaner is double insulated and no earth connection is necessary.

It  is  in  your  interest  to  ensure  that  the  plug  is  correctly  attached  to  the  mains  cable.  In  case  of  doubt,  have  it  done  by  a  qualified 

electrician, as Electrolux cannot regard the repair of faults on the plug connection as a service that can be given free of charge under 

the terms of the guarantee.

WARNING

The brush in the cleaning head rotates at high speed and can cause damage to the mains supply cable if the cleaner passes 

over it during cleaning operations.

Care should be taken to ensure that this does not happen. If the cleaning head has accidentally passed over the mains supply cable 

the following action should be taken:

1

.  Switch off and remove the plug from the socket outlet.

2

.  Examine the mains supply cable for damage (only after removing the plug from the socket outlet).

3.

  If there is any sign of damage to the supply cable it MUST be renewed.  The repair MUST be carried out by an Electrolux Service 

Agent or a similar qualified person.

4.

 

NEVER

 use the machine with a damaged mains supply cable.

Proprietary carpet conditioning and air freshening materials 

After  using  proprietary  carpet  conditioning  powders,  it  is  recommended  that  the  dust  cup  or  filters  be  changed.  Some  of  these 

preparations contain substances which if left in the vacuum cleaner for extended periods could damage the plastic mouldings which 

form the structure of the cleaner.

Many air fresheners, household deodorants, sprays and polishes contain a highly flammable gas propellant.

Because  of  this,  it  is  particularly  important  that  these  products  are  used  strictly  in  accordance  with  the  relevant  manufacturer’s 

instructions.

It is essential that none of the above products are sprayed directly into the vacuum cleaner or any of its filters, hose assembly, dust 

cup chamber or dust cup.

Fuse 

Cover

Fuse 

Blue

Brown

Cord 

Clamp

13 Amp Fuse

Thermal Cut Off

This vacuum cleaner has a special thermostat that protects the cleaner in case of motor overheating. If the cleaner suddenly shuts off, push the 
switch pedal once and unplug the cleaner. Check the cleaner for a possible source of overheating such as a full bag, a blocked hose or clogged 
filter. If these conditions are found, fix them and wait at least 30 minutes before attempting to use the cleaner. After the 30 minute period, plug the 
cleaner back in and turn on the switch. If the cleaner still does not run, please call Electrolux on 08706 055055.

Содержание Z4640 SERIES

Страница 1: ...mbly 5 6 Thermal Cut Off 3 7 Use 7 Accessories 8 Dirt Alert 9 Cyclonic Dust Cup 10 11 Brush Roll 12 Brush Roll Belt 12 Hose Blockage 13 Filters 14 HEPA Filter 15 Light Bulb 16 Problem Solving 18 IMPORTANT For any advice on your cleaner and to order dust bags filters and accessories please telephone Customer Care 08706 055055 www electrolux com ...

Страница 2: ...o not run vacuum cleaner over cord Keep cord away from heated surfaces Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or vacuum cleaner with wet hands Do not put any object into openings Do not use with any opening blocked keep free of d...

Страница 3: ...re that the plug is correctly attached to the mains cable In case of doubt have it done by a qualified electrician as Electrolux cannot regard the repair of faults on the plug connection as a service that can be given free of charge under the terms of the guarantee WARNING The brush in the cleaning head rotates at high speed and can cause damage to the mains supply cable if the cleaner passes over ...

Страница 4: ...e Electrolux vacuum cleaner and accessories supplied with it are protected in Great Britain and abroad by Patents or Registered Designs This appliance conforms with the requirements of the amended E E C directive No 89 336 EEC relating to electromagnetic compatibility EMC CE Electrolux may introduce modifications to their product from time to time and consequently the details given in this booklet ...

Страница 5: ...r pressure to slide handle into position 2 Attach handle with two 1 inch screws in the assembly packet Use either a slotted or Phillips head screwdriver NOTE Hand tighten with screwdriver to be sure both screws are firmly seated Groove Groove 1 2 3 From front of cleaner insert hose adapter into opening on top of unit Make sure the button on the hose adapter is secure in the hole on the unit 4 From ...

Страница 6: ...ation tool on handle pegs Handle Pegs 5 You will find your cord retainer on the handle above the upper cord hook Firmly push the electrical cord down into the cord retainer This will place the cord out of the way the next time you vacuum 6 Next wind the cord around the two cord hooks on the left side of cleaner NOTE For easier access to dust cup compartment when you store the electrical cord use a ...

Страница 7: ...g the hose or replace the filters 5 Wait at least 30 minutes before attempting to reuse the cleaner 6 After 30 minute cool down period plug the cleaner in and push the switch pedal The cleaner should turn on 7 If the cleaner still does not operate take it to any Electrolux Call Centre on 08706 055055 for repair authorisation 4 3 LOW HIGH 1 2 Cleaner Height Setting WARNING Avoid injury Keep loose cl...

Страница 8: ... models Use brush side to dust furniture blinds books lamps shelves Use upholstery side for curtains draperies cushions fabrics Turn ridge end to center Push wands together Pull apart Upholstery Side Grasp both wands near ridges Nested Extension Wands to add reach Extension Wands Some models use 1 wand Dusting Brush is for furniture blinds books lamp shades shelves On some models Upholstery Nozzle...

Страница 9: ...nt cleaning after the first few times you use your new Electrolux vacuum the red light should go on less NOTE The dirt alert feature is not intended to be used for above the floor cleaning with attachments Infrared emitter and sensor Hose Retainer Hose How to Check the Dirt Alert Sensors To check if dirt sensor is working properly 1 While the red light is on tip the vacuum backwards on rear wheels l...

Страница 10: ...ilter 1 Grasp yellow filter frame and twist counter clockwise to remove 2 Shake vigorously and brush off dust and lint 3 If filter needs further cleaning wash in warm water using a mild detergent 4 Do not submerge gray dust cup lid wipe only with a damp cloth 5 When all parts are completely dry replace filter on gray dust lid by twisting clockwise to snap and lock in place Use a Genuine Electrolux re...

Страница 11: ...rom cleaner body and dump debris in a waste container Reinstalling the Dust Cup To mount gray filter assembly into cleaner body make certain gray filter assembly is fully seated in top of dust cup Locate 3 mounting tabs at base of dust cup into slots at front of cleaner Pivot entire assembly fully into cleaner housing being certain that gray filter assembly wedges into top of rear housing Press top c...

Страница 12: ...ld cause the belt to rotate unevenly How To Replace Brush Roll Belt NOTE Turn off the switch and unplug the electrical cord before replacing belt Belt pulleys can become hot during normal use To prevent injury avoid touching the motor shaft when checking the belt 1 Lower handle to floor to change belt 2 Loosen but do not remove two screws to release hood Lift hood to remove 3 Lift left end of brush...

Страница 13: ... release from hose retainer 4 The hose is free of the cleaner Check for clogs in the hose retainer and throughout the hose assembly 5 Use a tool that will not puncture the hose Clear any debris from the hose retainer or the hose assembly that could restrict air flow 6 Flexing the hose may help loosen the clog 7 After the clog is removed make sure the hose assembly is reassembled onto the unit H o s...

Страница 14: ...ptied ToReplaceRinsableMicronExhaustFilter 1 Lower the handle Open exhaust filter door push toward the left side 2 Grasp filter and pull out 3 Push new filter into cleaner smooth side facing out 4 Close exhaust filter door push toward right side 2 3 Micron Filter Rinsing Directions for Rinsable Filters Filter can be rinsed up to 6 times Replace after 6 rinsings to retain filtration level performance fr...

Страница 15: ... HEPA filters 1 Push down latch and pull filter cassette back 2 Then lift filter up and remove To replace HEPA cartridge filters and Washable HEPA filters 1 Place bottom tabs of filter cassette into slots 2 Rotate filter toward cleaner 3 Push upward on the latch to secure into place NOTE To have the benefit of a sealed HEPA system you must use one of the HEPA cartridge filter systems NOTE For rinsing instr...

Страница 16: ...t the electrical cord before changing light bulb 1 Lower handle Remove two screws from lens cover 2 Pull lens cover from cleaner 3 Pull light bulb and socket toward front 4 Push light bulb into socket turn to release 5 Place new light bulb into socket turn to secure 6 Push light bulb and socket back so bulb will not touch lens cover 7 Replace lens cover 8 Secure with two screws 1 HOW TO MAINTAIN c...

Страница 17: ... end of the bonus hose Step 1 Remove the hose attached to the cleaner WARNING Always work with the cleaner below you pulling hose from side of cleaner not the back or the front of the cleaner Ensure it is positioned sideways up against the bottom step NEVER STAND ANY CLEANER ABOVE YOU NEVER POSITION ANY CLEANER ON THE STAIRS AS THIS COULD DAMAGE THE CARPET WARNING Never position any cleaner on the...

Страница 18: ...up fine dust the filter may not look dirty but a fine substance tends to reduce suction when it blocks the airflow through the filter s Hose Remove any clogs from the hose that restrict the airflow Check short hose in the base and long hose Refer to page 13 Headlight not working Light Bulb Replace light bulb Noise from the brush roll Brush Roll Remove hood and clean debris or items from the brush area r...

Страница 19: ......

Страница 20: ...x cleaner 1 wand 1 crevice tool 1 combination tool on some models 1 hose assembly 1 vacuum cleaner handle Accessory Items in This Carton 1 hardware package 2 screws Questions Call 08706 055055 Don t Forget to Use Genuine Electrolux Belts and Filters 1 dusting brush on some models 1 upholstery Nozzle on some models ...

Отзывы: