Diagnostics phases
Selector position
Components actioned
Operating conditions
Function checked
Displayed
parameters
1
All the LEDs light in
sequence. When a button is
pressed, the corresponding
LED lights (and the buzzer, if
featured, sounds)
Always activated
Operation of the
user interface
Button
codification
2
Door interlock
Washing solenoid
Door locked
Water level below
anti-flooding level
Maximum time 5
minutes
Water ducted
through washing
compartment
(**)Selection
position code
3
Door interlock
Pre-wash solenoid
Door locked
Water level below
anti-flooding level
Maximum time 5
minutes
Water ducted
through pre-wash
compartment
(bleach)
(**)Selection
position code
4
Door interlock
Pre-wash and wash solenoids
Door locked
Water level below
anti-flooding level
Maximum time 5
minutes
Water ducted
through conditioner
compartment
(**)Selection
position code
5
Door interlock.
Bleach/stains solenoid.
Door locked
Water level below
anti-flooding level
Maximum time 5
minutes
Water ducted through
bleach/stains
compartment
(**)Selection
position code
6
Door interlock
Washing solenoid if the level
of water in the tub is below
1st level
Heating element.
Door locked.
Water at 1st level.
Maximum time 10 min.
or up to 90ºC.
(*)
Heating
(**)Selection
position code
7
Door interlock.
(Washing solenoid if the level
of water in the tub is below 1st
level). Motor (55 rpm
clockwise, 55 rpm counter-
clockwise, 250 rpm impulse)
Door locked
Water level at 1st level.
Check for leaks from
the tub
(**)Selection
position code
8
Door interlock
Drain pump
Motor up to 650 rpm then at
maximum spin speed
Door locked
Water level lower than
anti-boiling level for
spinning
Drain and spin;
control of
congruence in
closure of level
pressure switches
(**)Selection
position code
9
--- ---
--- ---
---
10
Reading/cancelling last alarm
---
---
Alarm code
11, 12 ...24
All LEDs light in sequence. Pressing a button the corresponding LED lights (and the Buzzer
sounds, if featured)
(*)
In most cases, this time is sufficient to check the heating. However, the time can be increased by
repeating the phase without draining the water: for a moment to a different phase of the diagnostics cycle
and then back to the heating control phase (if the temperature is higher than 80°C, heating does not take
place).
(**) See table page 55.