Mount the new drum.
Fasten the tensioner and mount the counter weight with the tension strap.
Mount the heating elements, hoses and drain in the same position as before.
Fasten the belt. Make sure the belt is in position. Check the belt tension with a frequency meter or
similar. The frequency shall be 70 Hz ± 5. Adjust if necessary.
Remount the cabinet.
Connect the inlet hose and the vent hose to the drum.
Remount the level sensor, motor cable and earth cable at the back of the machine.
Remount the door lock and the rotation guard.
Fasten the cables with cable ties in the same position as before.
Remount the trim panel and the door.
Remount the top panel, the front— and back panels.
Connect the power to the machine.