28
Installation
32
6600
34
6601
33
5862
A
36
6604
35
6602
"HEAT"
Steam connection
Inlet pipes connected to the machine must be
equipped with a manual shut-off valve to facili-
tate installation and servicing.
The connection hose must be of type ISO/1307-
1983 or equivalent. Connection size at filter:
DN 15 (BSP 1/2").
Steam pressure required:
• minimum: 50 kPa (0.5 kp/cm
2
)
• maximum: 800 kPa (8 kp/cm
2
)
•
rec. pressure: 600 kPa (6 kp/cm
2
)
•
Remove top cover (A).
•
Remove casing (B).
• Mount the articulated nipple to the steam
valve.
• Mount the steam valve on the machine.
• Mount nipple, strainer and elbow. Note the
direction of the strainer. Mount steam hose to
the elbow.
Check that there are no sharp angles or bends
on the connected steam hose.
• Mount the hose with wires between steam
valve and machine.
Connect wires in the steam valve.
Connect ground cable to the terminal ground
connection.
Connect the ”HEAT” cable connector to the
”HEAT” terminal on the I/O board.
32
33
34
35
36
B