Installation manual
11
2.2
Technical data
W575N
W585N
W5105N
W5130N
W5180N
W5250N
W5330N
Weight, net
kg
116
114
152
154
207
262
307
Drum volume
litres
75
85
105
130
180
250
330
Drum diameter
mm
520
520
595
595
650
725
795
Drum speed during wash
rpm
49
49
46
46
44
42
40
Drum speed during extraction
rpm
587
587
548
548
525
497
474
G-factor, max.
100
100
100
100
100
100
100
Heating: Electricity
kW
2.0
2.0
5.4
3.0
13
18
23
kW
3.0
3.0
7.5
7.5
kW
5.4
5.4
10
10
kW
5.6
5.6
kW
7.5
7.5
Heating: Steam
x
x
x
x
x
x
x
Heating: Hot water
x
x
x
x
x
x
x
Frequency of the dynamic
force
Hz
9.8
9.3
9.1
9.1
8.8
8.3
7.9
Floor load at max extraction
kN
1.6 ± 1.9
1.7 ± 3.1
1.9 ± 2.5
2.4 ± 3.1
2.9 ± 3.9
3.8 ± 4.9
4.6 ± 5.6
Sound power/pressure level at
extraction*
dB(A)
68/53
68/53
68/53
68/53
70/55
70/54
72/57
Sound power/pressure level at
wash*
dB(A)
62/48
62/48
62/47
62/47
67/52
66/50
67/51
* Sound power levels measured according to ISO 60704.
2.3
Connections
W575N
W585N
W5105N
W5130N
W5180N
W5250N
W5330N
Water valves
DN
BSP
20
3/4”
20
3/4”
20
3/4”
20
3/4”
20
3/4”
20
3/4”
20
3/4”
Recommended water pressure
kPa
200–600
200–600
200–600
200–600
200–600
200–600
200–600
Functioning limits for water valve
kPa
50–1000
50–1000
50–1000
50–1000
50–1000
50–1000
50–1000
Capacity at 300 kPa
l/min
20
20
20
20
30
60
60
Drain valve
⌀
outer
mm
75
75
75
75
75
75
75
Draining capacity
l/min
170
170
170
170
170
170
170
Steam valve connection
DN
BSP
15
1/2”
15
1/2”
15
1/2”
15
1/2”
15
1/2”
15
1/2”
15
1/2”
Recommended steam pressure
kPa
300–600
300–600
300–600
300–600
300–600
300–600
300–600
Functioning limits for steam valve
kPa
50–800
50–800
50–800
50–800
50–800
50–800
50–800