background image

Installation manual

Washer extractor

W575N, W585N, W5105N, W5130N, W5180N,

W5250N, W5330N

Type W3...

Original instructions

438 9055-30/EN

2019.01.30

Содержание W3 SERIES

Страница 1: ...Installation manual Washer extractor W575N W585N W5105N W5130N W5180N W5250N W5330N Type W3 Original instructions 438 9055 30 EN 2019 01 30 ...

Страница 2: ......

Страница 3: ... 2 1 Machine with connectors 25 6 2 2 Machine without connectors 26 6 2 3 Outputs 27 6 2 4 Inputs 28 7 Drain connection 29 8 Electrical connection 29 8 1 Electrical installation 29 8 2 Electrical connections 30 8 3 Machine connection 32 8 4 Functions for I O cards 33 8 4 1 External coin meter Central payment 2A 33 8 4 2 Central payment 2B 34 8 4 3 Central payment 2C 35 8 4 4 Outputs for detergent ...

Страница 4: ......

Страница 5: ...nected the operator must see that the ma chine is disconnected that the plug is removed and remains removed from any point to which he has access If this is not possible due to the construction or installation of the machine a disconnection with a locking system in the isolated position shall be provided In accordance with the wiring rules mount a multi pole switch prior to the machine to facilita...

Страница 6: ...ance is not intended for use by persons including chil dren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given super vision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to en sure that they do not play with the appliance 1 1 General safety information The machi...

Страница 7: ...nt container 4 Cold water 5 Hot water 6 Re used water 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D1 D2 E F G W575N 660 681 1131 356 409 1099 835 80 W585N 660 722 1133 357 410 1153 836 80 W5105N 720 697 1217 367 424 1187 920 80 mm H I J K L M N O W575N 1034 217 124 1014 914 278 101 199 W585N 1035 217 124 1015 915 278 103 199 W5105N 1119 217 124 1099...

Страница 8: ...ting panel 2 Door opening W5130N 365 mm 3 Detergent container 4 Cold water 5 Hot water 6 Re used water 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D1 D2 E F G W5130N 720 787 1216 367 424 1337 920 80 mm H I J K L M N O W5130N 1119 217 124 1099 999 278 103 212 ...

Страница 9: ...l 2 Door opening W5180N 395 mm 3 Detergent container 4 Cold water 5 Hot water 6 Re used water 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D1 D2 E F G W5180N 750 914 1345 439 500 1440 1048 80 mm H I J K L M N W5180N 1247 297 217 1227 1127 278 104 mm O P W5180N 223 132 ...

Страница 10: ...ent container 4 Cold water 5 Hot water 6 Re used water 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D1 D2 E F G W5250N 830 1029 1426 468 532 1599 1129 80 W5330N 910 1114 1465 504 568 1686 1168 80 mm H I J K L M N W5250N 1328 327 247 1288 1203 278 100 W5330N 1367 347 247 1327 1247 278 104 mm O P W5250N 265 162 W5330N 209 162 ...

Страница 11: ... level at extraction dB A 68 53 68 53 68 53 68 53 70 55 70 54 72 57 Sound power pressure level at wash dB A 62 48 62 48 62 47 62 47 67 52 66 50 67 51 Sound power levels measured according to ISO 60704 2 3 Connections W575N W585N W5105N W5130N W5180N W5250N W5330N Water valves DN BSP 20 3 4 20 3 4 20 3 4 20 3 4 20 3 4 20 3 4 20 3 4 Recommended water pressure kPa 200 600 200 600 200 600 200 600 200 ...

Страница 12: ... in a crate or box Remove packing from the machine Remove the front and rear panel Remove the bolts between the machine and pallet There is one to the right in the front of the machine and another diagonally opposed to it at the back of the machine fig W00846 Remove the machine from the pallet Note When moving the machine handle it with care Place the machine on its final position ...

Страница 13: ... a floor drain or open drain The machine should be positioned so that there is plenty of room for working both for the user and service personnel The figure shows minimum distance to a wall and or other machines 500 mm 20 inch 25 mm 1 inch 25 mm 1 inch fig W00176D ...

Страница 14: ...ill two holes 10 mm about 40 mm deep 1 for the expansion bolts in the positions shown 1 fig 5989B mm A B C D E F G H I W575N 685 660 495 395 115 635 W585N 725 660 495 445 115 665 W5105N 700 720 575 385 120 695 W5130N 785 720 575 495 120 760 W5180N 875 750 635 570 120 855 W5250N 950 830 715 635 125 955 W5330N 1035 910 790 695 135 1050 810 10 95 After the machine has been placed over the other four ...

Страница 15: ... Floor In this type of machine the drum is attached directly to the frame As a result the floor under the machine must be stable enough to absorb the dynamic forces generated during spin cycles For that reason the mounting bolts must be cast into the floor material itself When fixing the machine to an existing cement floor it must be and at least 150 mm thick If the floor is less than 150 mm thick...

Страница 16: ...nd check that the sides of the hole are tapered outward so that the longest side at the bottom measures 120 mm more than at the top fig 0899 Make the mould for the plinth Moisten the hole well and apply cement to the sides and bottom 4 bolts must be set into the concrete of the machine base The bolts need to project 40 mm out of the base Pour the concrete into the prepared base mould and make sure...

Страница 17: ...ate the bolt into the hole so that the glass ampule is broken and its contents mixed 5 Rotate the bolt to correct depth Note Do not rotate the bolt against the concrete bottom Check that the chemicals have filled the hole completely 6 Remove the drilling machine with the mounting tool Hold the bolt with one hand Let the bolt harden before the machine is mounted 1 2 3 4 5 6 fig 5917A Time for harde...

Страница 18: ...ers 3 Apply sealant to the hole cut in the vinyl floor covering Insert the washer Use sealant to seal around the washer between the vinyl and the washer 4 Put the machine into place Check that the machine is in level If it is not use spacers where required between floor and machine If chemical anchors are used do not use the nut and washer supplied with them Fix the machine in place using the wash...

Страница 19: ...the machine close to a floor drain or open drain The machine should be positioned so that there is plenty of room for working both for the user and service personnel The figure shows minimum distance to a wall and or other machines A A B fig X00959 A 25 mm B 500 mm ...

Страница 20: ...ine is placed in level from side to side as well as front to rear If the machine is not properly levelled it may result in out of balance without a real out of balance in the drum fig 5463A After the machine has been in use for a while check and re tighten the nuts if necessary Floor In this type of machine the drum is attached directly to the frame As a result the deck under the machine must be s...

Страница 21: ...nd check that the sides of the hole are tapered outward so that the longest side at the bottom measures 120 mm more than at the top fig 0899 Make the mould for the plinth Moisten the hole well and apply cement to the sides and bottom 4 bolts must be set into the concrete of the machine base The bolts need to project 40 mm out of the base Pour the concrete into the prepared base mould and make sure...

Страница 22: ...6 mm 7 Washer 72 x 72 x 8 mm L profile dimensions W575N W5130N 80 x 80 x 8 W5180N W5330N 100 x 100 x 10 mm mm A B C D E F G H W575N 660 685 495 80 395 115 W585N 660 725 495 80 445 115 W5105 N 720 700 575 75 385 120 W5130 N 720 785 575 75 495 120 W5180 N 750 875 635 55 570 120 W5250 N 830 950 715 55 635 125 W5330 N 910 1035 790 60 695 135 mm I J K L M W575N 30 455 85 W585N 30 505 85 W5105 N 10 30 4...

Страница 23: ...ne Information is also available on the panel above the connections Water type Water connection 1 W575N W585N Cold W575N W585N 1 Cold 1 2 W575N W585N W5105N W5130N Cold and hot W575N W585N W5105N W5130N 1 Cold 2 Hot 1 2 3 W5180N W5250N W5330N Cold and hot W5180N W5250N W5330N 1 Cold 2 Hot 3 Cold for detergent container Hot There is also an extra water valve which can be used for hard water if soft...

Страница 24: ...hon breaker A 17 mm used for external dosing systems or systems for re use of water B 6 mm used for external dosing systems only C Only used for external liquid manifold Separate instructions enclosed when ordering A B C Always connect hoses on connections A with a hose clamp For connections B if the hoses are made of a soft material such as silicone or similar use a cable tie to fasten the hose o...

Страница 25: ...the power supply to A For Efficient dosing system the cables are delivered with the machine Connect the power supply cable to the machine A and the other end of the cable together with the cable from Effi cient Dosing in a connection box or with plug and receptacle Connect one end of the cable to the Efficient Dosing Controller J2 and the other end to the machine B Connection box B 1 2 3 4 1 2 3 4...

Страница 26: ... O board which is located to the right of the incoming power supply The I O board has edge connectors for connecting external dosing systems Edge connectors on the I O board can be loosened for connecting cables fig 6572 11 N 18 Program run 12 Signal 1 13 Signal 2 14 Signal 3 15 Signal 4 16 Signal 5 ...

Страница 27: ... the outputs 0 5 A Signals for external liquid supplies 1 5 are connected to 12 16 where connector 12 Signal 1 13 Signal 2 14 Signal 3 15 Signal 4 16 Signal 5 fig 6236B 6M14 6F01 6R01 6F02 Other programs Signal 1 Pre wash Pre wash Pre wash Pre wash Signal 2 Main wash Main wash Main wash Main wash Main wash Signal 3 Softener Softener Softener Softener Softener Signal 4 Mop last rinse Desinfection P...

Страница 28: ...s too high 24V Connection 8 may be connected if the program is to pause e g while detergent is being dosed The figure shows an example of engaging a 24V pause signal The program will pause for as long as the pause sig nal remains activated high fig 6266 Connection 7 If this is connected an error message will be displayed if any of the chemical tanks are empty The pro gram will continue however The...

Страница 29: ...uipment such as earth leakage circuit breakers are not necessary If you still want to connect your machine across an earth leakage circuit breaker please remember the following contact a skilled authorised installation company to ensure that the appropriate type of breaker is chosen and that the dimensioning is correct for maximum reliability connect only one machine per earth leakage circuit brea...

Страница 30: ...ting alternative Main voltage Hz Heating power kW Total power kW Recommended fuse A Electric heated 220 240V 1 50 60 3 0 7 5 10 0 3 3 7 8 10 3 20 35 50 220 240V 3 50 60 7 5 10 0 7 8 10 3 25 35 380 415V 3N 50 60 7 5 10 0 7 8 10 3 16 20 440V 3 60 7 5 10 0 7 8 10 3 16 480V 3 60 7 5 10 0 7 8 10 3 16 Non heated Steam heated 220 480V 1 50 60 0 8 10 W5130N Heating alternative Main voltage Hz Heating powe...

Страница 31: ... Main voltage Hz Heating power kW Total power kW Recommended fuse A Electric heated 220 240V 3 50 60 19 8 23 0 21 0 24 2 63 380 415V 3 50 60 19 8 23 0 21 0 24 2 35 50 440V 3 60 21 0 23 0 22 2 24 2 35 480V 3 60 22 8 23 0 24 0 24 2 35 220 230V 3 50 60 19 1 20 3 63 380 400V 3 50 60 19 1 20 3 35 Non heated Steam heated 220 480V 1 50 60 1 4 10 Max permitted impendance 0 26 Ohm The impendance in the mai...

Страница 32: ...2 3N AC L1 L2 L3 N 1N 1 L1 L2 N 3N AC L1 L2 L3 N Single phase machines may be powered either by connection between a phase and neutral or by connecting be tween two phases Example Machines for 220 240V single phase may be powered from 380V or 400V or 415V system by connection between a phase and neutral or from 220V or 230V or 240V system by connection between two phases ...

Страница 33: ...schematic can be one of the following 8 4 1 External coin meter Central payment 2A The signal received from external coin meters must be a pulse between 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended between two pulses fig 6606A ...

Страница 34: ...ayment system must transmit a start pulse to the machine The start pulse can be either 230V or 24V In order to receive a feedback signal once the machine has started 230V or 24V must be connected to connection 19 The feedback signal on connection 18 remains active high during the entire program fig 6316A ...

Страница 35: ...chine once permission has been granted to start the machine The signal must remain active high until the machine starts A feedback signal will be present on connection 18 and remain active high whilst the machine door is closed but the program has not started The feedback signal is powered by 230V or 24V from connection 19 fig 6313A ...

Страница 36: ...ines with the coin program package By maintaining an active high signal on connection 5 Price red the price of the program can be reduced This function has a number of uses including providing reductions during a specific period of the day Whilst the signal re mains active high the price of the program is reduced by the percentage entered in the price programming menu fig 6314A ...

Страница 37: ...n 108 1 2 Con 109 1 2 3 4 5 6 RE106 RE105 RE104 RE103 RE102 Con 107 1 2 3 RE101 Inp Con 115 Function I O s PTD5 Type of I O card 5V Start permitted Central booking payment 230V 0V 24V 24V Start permitted Central booking payment Neutral Line Com 24V Com 100 240V Blocking of start Heating pause Liq det empty Temporary pause Common outputs Power for outputs Common Liquid det sign 1 Liquid det sign 2 ...

Страница 38: ...ection 3 Price reduction the price of the program can be reduced This function has a number of uses including providing reductions during a specific period of the day Whilst the sig nal remains active high the price of the program is reduced by the percentage entered in the price programming menu fig 6636 ...

Страница 39: ... 357 355 358 354 353 356 3 4 1 2 K22 5 6 L1 T1 L2 T2 L3 T3 N1 N Q1 3 4 5 6 1 2 K21 E2 E3 E1 L1 L2 L3 N PE 220 240V 1N with reduced heating power Remove From L3 From L2 fig W00620 Remount the cover panel to the electrical connections Connect the power to the machine Check that all terminals and wires are secure and test run the machine on a short program with 60 C to ensure that it does heat up 9 S...

Страница 40: ...on the connected steam hose fig 5862C Mount the hose with wires between steam valve and machine Connect the wires to the steam valve Connect ground cable to the terminal ground connection Connect the HEAT cable connector to the HEAT terminal on the I O board HEAT fig 6604B Steam pressure required minimum 50 kPa 0 5 kp cm2 maximum 800 kPa 8 kp cm2 recommended 600 kPa 6 kp cm2 Note A steam heated ma...

Страница 41: ...Select language from the list on the display This will be the language that all display messages program names etc will be presented in 10 2 Set time and date Select YES and press the control knob to get to the menu TIME DATE Activate the SET TIME menu and set the correct time Save the settings Activate the SET DATE menu and set the correct date Start by setting the year Set the year Exit to conti...

Страница 42: ...f in a differentiated way according to their different characteristics e g met als oils greases plastic rubber etc Different regulations are in force in the various countries therefore comply with the provisions of the laws and com petent bodies in the country where scrapping takes place In general the appliance must be taken to a specialised collection scrapping centre Dismantle the appliance gro...

Страница 43: ...y where the appliance is used All the packing materials are environmentally friendly They can be safely kept recycled or burned in an appropriate waste incineration plant Recyclable plastic parts are marked as following examples PE Polyethylene Outer wrapping Instructions bag PP Polypropylene Straps PS Polystyrene foam Corner protectors ...

Страница 44: ...Electrolux Professional AB 341 80 Ljungby Sweden www electrolux com professional Share more of our thinking at www electrolux com ...

Отзывы: